Laserfiche WebLink
t <br /> ece� <br /> Page 3 of 8 LCO,C„M <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: ❑ Piping Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other(Spec) <br /> Test Method Used: ® Pressure ❑Vacuum ❑ Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: Pressure Gauge Equipment Resolution: 0-30 psi <br /> Piping Run# 1 (87) Piping Run#2 (91) Piping Run# Piping Run# <br /> Piping Material: Fiberglass Fiberglass <br /> Piping Manufacturer: AO Smith AO Smith <br /> Piping Diameter: 3 in 3 in <br /> Length of Piping Run: 85 feet 90 feet <br /> Product Stored: Gasoline Gasoline <br /> Method and location of 87 Sump- Disp. 91 Sump- Disp. <br /> piping-run isolation: <br /> Wait time between applying <br /> pressure/vacuum/water and 5 min 5 min <br /> starting test: <br /> Test Start Time: 10:20 AM 10:15 AM <br /> Initial Reading(Ri): 5 psi 5 psi <br /> Test End Time: 11:20 AM 11:15 AM <br /> Final Reading(RF): 5 psi 4 psi <br /> Test Duration: 60 min 60 min <br /> Change in Reading(RF-R,): 0 1 <br /> Pass/Fail Threshold or 5 psi 5 psi <br /> Criteria: <br /> Test Result: Pass ❑Fail ® Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑ Fail <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />