M] <br />Page 5 of 8 <br />7 TTI�T'lTi i�-iITCPTi NQTR CnNTATNMFNT ITTnC) TFgTTNf <br />ecov/ <br />ECO-CHEK COMPLIANCE <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Tape Measure <br />Equipment Resolution: 1/16 in <br />SEEMEMIMMEM <br />MEN= <br />UDC # 1-2 <br />UDC # 3-4 <br />UDC # 5-6 <br />UDC # 7-8 <br />UDC Manufacturer: <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC Material: <br />Steel <br />Steel <br />Steel <br />Steel <br />UDC Depth: <br />10 in <br />10 in <br />10 in <br />10 in <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />0 in <br />0 in <br />0 in <br />0 in <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />0 in <br />0 in <br />0 in <br />0 in <br />Condition of UDC prior to <br />testing: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC Tested <br />8" above prod. piping <br />8" above prod. piping <br />8" above prod. piping <br />8" above prod. piping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />❑Yes [:]No ®NA <br />❑Yes ❑No ®NA <br />❑Yes [-]No ®NA <br />❑Yes ❑No ®NA <br />Turbine shutdown response time <br />* See comments <br />* See comments <br />See comments <br />* See comments <br />Is system programmed for fail- <br />safe shutdown?` <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />Was fail-safe verified to be <br />o erational?* <br />❑Yes [-]No ®NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />5 min <br />5 min <br />5 min <br />5 min <br />Test Start Time: <br />9:15 AM <br />9:15 AM <br />9:15 AM <br />9:15 AM <br />Initial Reading (RI): <br />8 <br />8 <br />8 <br />8 <br />Test End Time: <br />10:15 AM <br />10:15 AM <br />10:15 AM <br />10:15 AM <br />Final Reading (RF): <br />8 <br />8 <br />7 <br />8 <br />Test Duration: <br />60 min <br />60 min <br />60 min <br />60 min <br />Change in Reading (RF -RI): <br />0 <br />0 <br />1 <br />0 <br />Pass/Fail Threshold or Criteria: <br />1/16 in <br />1/16 in <br />1/16 in <br />1/16 in <br />Test Result: <br />®i Pass' ❑ Fail <br />10 Pass' ., ❑ Fail <br />❑ Pass ' ®• )Fail <br />Z Pass ❑ Faii <br />Was sensor removed for testing? <br />❑Yes ❑No ®NA <br />❑Yes [:]No ®NA <br />❑Yes ❑No ®NA <br />❑Yes ❑No ®NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />[:]Yes❑No ®NA <br />❑Yes ❑No ®NA <br />❑Yes [-]No ®NA <br />❑Yes [:]No ®NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to Any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />