Laserfiche WebLink
pA0000086 pnuu 1m4ucou 08/e/2018 <br />Exouo-01 Rev. 09/22/16 Page 1pys Underground Storage Tank Program om <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.saqov.o[gjgtLd <br />Lk f'k low <br />Facility Name: <br />San Joaquin General Hospital <br />Facility Phone: <br />(209) 468-6812 <br />Date: <br />August 21, <br />2018 <br />Facility Address: <br />500 W Hospital Rd, French Camp, CA 95231 <br />CERS ID: <br />.10643278 <br />Inspection Contact: <br />Nicholas Graham -Lewin <br />Title: <br />Authorized representative <br />Phone: <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For: <br />El Inspection N Photos Z Samples <br />Consent Given By: <br />I Alfredo Garcia, Central P1 Int En 'neer <br />Service Technician Onsitec Exp. Date: <br />Zane Nimmo/ Eric Molgaard 06/02/2019 <br />Designated Operator: <br />Nicholas Graham -Lewin <br />Exp. Date: <br />04/20/2020 <br />Service Technician Manufacturer's Training <br />CCR California Code of Regulations HSC Health and Safety Code CFR Code of Federal Regulations <br />V Violation R =Repeat violation COS= Corrected on site during inspection <br />7777 <br />101 <br />HSC 25284 <br />Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees <br />oV <br />o R ii COS <br />102 <br />HSC 25284(a)(3)(A)/ <br />No written agreement between tank owner and tank operator to monitor the tank system <br />oV <br />oR Ei COS <br />103 <br />HSC 25292.2, 25299.30 <br />Current financial responsibility documents not submitted <br />o V <br />D R Ei COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />o V <br />o R ii COS <br />105 <br />CCR 2632(d)(1), <br />Failed to have an approved UST monitoring plan <br />Ei V <br />o R oCOS <br />106 <br />CCR 2632(d)(2), <br />Failed to have an approved UST response plan <br />o V <br />oR c COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />ii V <br />Li R c COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />o V <br />c R oCOS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />Ei V <br />oR oCOS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />Ei V <br />oR oCOS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />Ei V <br />oR Li COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />o V <br />o R o COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />Lj V <br />Li R oCOS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />oV <br />ii R Ei COS <br />115 <br />CCR 2715(a) <br />Failed to submit to EHD notification of designated operator identification or change w/in 30 days <br />nV <br />oR EiCOS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />Ei V <br />o R o COS <br />117 <br />CCR 2663(h) <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />c V <br />Ei R o COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />o V <br />o R oCOS <br />119 <br />HSC 25299(a)(8), <br />Documents were falsified or misrepresented <br />o V <br />o R Li COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of I nsta Ratio n/M od ifi cation <br />o V <br />Ei R ii COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />ii V <br />ii R Ei COS <br />122 <br />CCR 2631 (1) <br />Failure to submit and maintain UST system component statement of compatibility for substance stored <br />o V <br />o R oCOS <br />Wt <br />-T <br />2 01 <br />CCR 2712(b) <br />Failure to maintain monitoring, maintenance, and follow up action records <br />mV <br />m R o COS <br />pA0000086 pnuu 1m4ucou 08/e/2018 <br />Exouo-01 Rev. 09/22/16 Page 1pys Underground Storage Tank Program om <br />