My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 1:54:59 PM
Creation date
6/3/2020 9:50:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231614_500 W HOSPITAL_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FA0000086 PR0231614 SCO01 08/21/2018 <br />EHD 23-01 Rev. 09/22/16 Page 2 of 5 Underground Storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: WWW.sjgov.org/ehd <br />vv <br />�01II�Qlla� pit'' r , r kal�. <br />l.3 ��., ,rthr L ,. -'ny S'`.., '.A.."+b". iQ ,S+.ld ., fix'y,. ,.'e.;s'G. ..Xr#'. i �` ,:.. "^ ...IWI <br />Facility Name: <br />San Joaquin General Hospital <br />Facility Address: <br />500 W Hospital Rd French Camp <br />Date: <br />August 21 <br />2018 <br />"10"""M-. tvi <br />202 <br />CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />❑ V <br />❑ R <br />❑ COS <br />203 <br />CCR 2712(b) <br />Failure to maintain records of repairs, lining, and upgrades on site, for the life of the UST <br />❑ V <br />❑ R <br />❑ COS <br />204 <br />CCR 2712(i) <br />Current monitoring plan approved by the EHD not found on site <br />❑ V <br />❑ R <br />❑ COS <br />205 <br />CCR 2712(1), 2634(e) <br />Failure to submit a current UST Response Plan and have it available onsite <br />❑ V <br />❑ R <br />❑ COS <br />206 <br />CCR 2712 <br />Failure to comply with UST operating permit conditions <br />■ V <br />■ R <br />❑ COS <br />207 <br />HSC 25294 <br />Failed to record unauthorized release from primary containment <br />❑ V <br />❑ R <br />❑ COS <br />208 <br />CCR 2650(e), 2652 <br />Failed to notify the EHD of a reportable unauthorized release <br />❑ V <br />❑ R <br />❑ COS <br />209 <br />CCR 2715(c) <br />Designated operator did not inspect all required items and/or the inspection reports not completed <br />■ V <br />■ R <br />❑ COS <br />210 <br />CCR 2715(e) <br />Designated operator monthly inspection reports not maintained on site for at least 12 months <br />❑ V <br />❑ R <br />❑ COS <br />211 <br />CCR 2715(f)(2) <br />Designated operator employee training not performed or log not kept <br />❑ V <br />❑ R <br />❑ COS <br />212 <br />CCR 2715(f)(2) <br />Unstaffed facility failed to have or implement a training program approved by the EHD <br />❑ V <br />❑ R <br />❑ COS <br />213 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />❑ V <br />❑ R <br />❑ COS <br />214 <br />HSC 25281.5(b)(3) <br />Unburied emergency generator fuel piping not visually inspected at least monthly or log kept <br />❑ V <br />❑ R <br />❑ COS <br />215 <br />CCR 2712(i) <br />Failure to retain a copy of the permit to operate at the facility <br />❑ V <br />❑ R <br />❑ COS <br />rye,X' <br />632"%!, <br />3eQ <br />301 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />❑ V <br />❑ R <br />❑ COS <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary into secondary containment (pre -Jul 2003) <br />❑ V <br />❑ R <br />❑ COS <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003 -Jun 2004) <br />❑ V <br />❑ R <br />❑ COS <br />304 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) <br />❑ V <br />❑ R <br />❑ COS <br />305 <br />j HSC 25290.1(e) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained <br />❑ V <br />❑ R <br />❑ COS <br />306 <br />CCR 2630(d) <br />Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity <br />❑ V <br />❑ R <br />❑ COS <br />307 <br />CCR 2631(g), 2632(c) <br />Monitoring system of the interstitial space of a double walled system not maintained <br />❑ V <br />❑ R <br />❑ COS <br />308 <br />CCR 2636(f) <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm <br />❑ V <br />❑ R <br />❑ COS <br />309 <br />CCR 2636(f)(1) <br />Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product <br />❑ V <br />❑ R <br />❑ COS <br />310 <br />CCR 2636(f)(5) <br />Failure to meet monitoring requirements in lieu of annual line tightness test <br />❑ V <br />❑ R <br />❑ COS <br />311 <br />CCR 2638(a), 26410) <br />Failed to properly program or operate leak detection equipment <br />❑ V <br />❑ R <br />❑ COS <br />312 <br />CCR 2638(f), 2641(i) <br />Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced <br />❑ V <br />❑ R <br />❑ COS <br />313 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failure to construct, operate, and maintain primary containment as product -tight <br />❑ V <br />❑ R <br />❑ COS <br />314 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failed to have secondary containment or secondary containment not tight <br />❑ V <br />❑ R <br />❑ COS <br />315 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />❑ V <br />❑ R <br />❑ COS <br />316 <br />HSC 25290.1(c3), <br />25290.2(c3) <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />❑ V <br />❑ R <br />❑ COS <br />317 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V <br />❑ R <br />❑ COS <br />318 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V <br />❑ R <br />❑ COS <br />FA0000086 PR0231614 SCO01 08/21/2018 <br />EHD 23-01 Rev. 09/22/16 Page 2 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.