My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
983
>
2300 - Underground Storage Tank Program
>
PR0231691
>
COMPLIANCE INFO_2001-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 4:56:44 PM
Creation date
6/3/2020 9:50:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2009
RECORD_ID
PR0231691
PE
2361
FACILITY_ID
FA0003593
FACILITY_NAME
Nella Oil #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
Blvd
City
Manteca
Zip
95336
APN
221-15-06
CURRENT_STATUS
01
SITE_LOCATION
983 Moffat Blvd
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231691_983 MOFFAT_2001-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MMPILRTR�*WIX <br />T@St MetiloCil Bj(: s Manufacturer O Industry Standard O Professional Engr, 0 Other (see below) <br />__. <br />Test Method U. <br />O Pressure • Vacuum 0 Hvdrostatl&0 Other: (see below) <br />Measuring Equipment Used'. VaCUM Gauge (range 0 WIN fnchesJig) <br />Description Tank) Tank'#2 lank #3 <br />Tank Manufacturer <br />Modern <br />Modern <br />Modern <br />Tank TypeSteel <br />Steel <br />Steel <br />Tank Capacity <br />8,000 <br />4,000 <br />12,000 <br />Product Stored <br />Gasoline - 87 <br />Gasoline -91 <br />Diesel <br />Is this a multi -compartment tank? <br />Yes <br />Yes <br />No <br />Brine filled or Dry Annular? <br />Dry <br />N/A <br />Dry <br />(if brine filled, perform no vacuum testing) <br />Monitoring system show normal annular? <br />Unknown <br />N/A <br />Unknown <br />Is water table above tank bottom? <br />Unknown <br />N/A <br />Unknown <br />Was sensor removed for testing? <br />Yes <br />N/A <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />N/A <br />Yes <br />Wait time for vacuum to stabilize (hr: min) <br />0:20 <br />0:11 <br />Test start time <br />8:40 AM <br />8:41 AM <br />Initial vacuum (inches Hg) <br />7 <br />7 <br />Test end time <br />9:40 AM <br />9:41 AM <br />Final vacuum (inches Hg) <br />7 <br />7 <br />Test duration (hours:minutes) <br />1:00 <br />1:00 <br />Change in vacuum (inches Hg) <br />0 <br />0 <br />Pass/Fail threshold (inches Hg/hour) <br />2 <br />2 <br />TEST RESULT <br />PASS <br />PASS <br />Comments: <br />Tank #2 is the second compartment of a 2 compartment tank <br />(#1 / #2). <br />No annular testing performed. <br />Note: This facility is an unmanned cardlock. <br />The monitoring <br />system was not accessible <br />to verifv sensor status noon start or completion of the testing. <br />0 2002 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.