EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
444
>
2300 - Underground Storage Tank Program
>
PR0231692
>
COMPLIANCE INFO_2001-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 11:29:54 AM
Creation date
6/3/2020 9:51:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2009
RECORD_ID
PR0231692
PE
2361
FACILITY_ID
FA0000212
FACILITY_NAME
Mossdale Chevron
STREET_NUMBER
444
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
444 W MOSSDALE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231692_444 W MOSSDALE_2001-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PIPING SUMP CONTAINMENTTI <br />Testi iethOC X3jf: Maufatnrec ®industry Standard o Professional fngr. o Other see below) <br />Test Meth e O Vacuum W:1_ Hydros#attic ( t?ther(seetaelaw) <br />MeaSUn*llg Equipment U5@dL@1f@l Chane In tea of ]Caldwell System 20Q1 /Walton Engineering] <br />®escrip#ion Tank #1 Tank Tank #3 <br />Sump Material <br />FRP <br />FRP <br />FRP <br />Sump Diameter (inches) <br />42" <br />42" <br />42" <br />Sump Depth (inches) <br />58" <br />59" <br />62" <br />Product Stored <br />Gasoline - 87 <br />Gasoline - 91 <br />Diesel <br />Height from tank top to highest <br />20" <br />21" <br />10" <br />piping penetration <br />Height from tank top to lowest <br />16" <br />16" <br />20" <br />electrical penetration <br />Condition of sump prior to testing <br />Dry <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />XxxxEntire <br />Entire <br />Is system programed for fail-safe operation? <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Wait time for water level to stabilize (hr:min) <br />0:20 <br />0:16 <br />0:12 <br />Depth of water level from tank top (inches) <br />23" <br />26" <br />24" <br />Test start time <br />x 9:35 AM <br />9:36 AM <br />9:37 AM <br />Test end time <br />10:05 AM <br />10:06 AM <br />10:07 AM <br />Test duration (hr:min) <br />0:30 <br />0:30 <br />0:30 <br />Change in water level (t 0.000 inches) <br />0.0000.000 <br />0.000 <br />Pass/Fail threshold (�0.®005 inches / %: Hr.) <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT LT <br />PASS <br />PASS <br />PASS <br />Comments: <br />0 2002 Watton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.