My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 9:07:22 AM
Creation date
6/3/2020 9:51:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> W" <br /> $ a <br /> "��;r �� �- �� .0 oder round atoraQe�� ank�Pro ram#Ins�'yect'onegort <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#2076* 1030 S OLIVE ST, STOCKTON July 07, 2016 <br /> Sistem 0lservations �. <br /> .,, .., <br /> 326 CCR 2631.1 UST system not compatible with the substance stored ❑V ii ❑COS <br /> r327 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 328 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 329 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> r401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> Othe Vions _ .. <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> r <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents are not correct. The Chief Financial Officer Letter line 1 is not atlleast ten times <br /> line 4 as required. Current financial responsibility documents are required to be submitted annually. Immediately log <br /> into the California Environmental Reporting System(CERS) at http://cers.calepa.ca.gov/, and upload the required <br /> documents. <br /> This is a minor violation. <br /> 209 CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training for Harpal Harit was not current. The designated operator shall train <br /> facility employees for which he or she is responsible in the proper operation and maintenance of the UST system <br /> once every 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a minor violation. <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.