My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 9:07:22 AM
Creation date
6/3/2020 9:51:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department / t <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 s <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> '� ,r <br /> Under, rounS�ora <br /> f9gram; ect'onle ort s <br /> r a a p [ <br /> w, ,„, .. ..,,,x,`!+, ., ....`.,�' .r., ,r<' t ......, }r; =.!Y <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#2076* 1030 S OLIVE ST, STOCKTON July 07, 2016 <br /> Item# Remarks <br /> 309 CCR 2636(f)(1) Monitoring in sump/ UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo Float and Chain assembly in UDC 1/2 failed to stop the flow of product at the dispenser when tested to <br /> ensure continuous monitoring of the tank system. All monitoring equipment shall be maintained to activate an audible <br /> and visual alarm or stop the flow of product at the dispenser when it detects a leak. The technician cleaned the float <br /> and retested with passing results. This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 87 STP sump on the south west side and in the 91 STP sump on the south west and north <br /> east side. If water could enter into the secondary containment by precipitation or infiltration, it must be removed and <br /> disposed of properly. The service technician removed 1/2 gallon of liquid from the 87 STP and 91 STP sumps. <br /> Ensure that all sumps and annular spaces are maintained free of liquid. <br /> This is a repeat violation, Class II, <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting a <br /> 3-gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. A"UST Retrofit <br /> Verification with Inspector Already Onsite”form has been completed and provided to the operator and contractor. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> NOTES: <br /> -Verified all sensors at lowest point. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITHBRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTIONATA Y TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: Inspector: Inspector Phone: <br /> i Printed Name and Title: FATINAH ZAREEF, REHS (209) 953-7311 <br /> y _ � <br /> t <br /> Page 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.