My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 9:07:22 AM
Creation date
6/3/2020 9:51:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT4WING SYSTEM CERTI1WAT16 CuE-_1 V CZLI <br />MAKE / MODEL OF MONITORING SYSTEM: Gilbarco EMC JUL 2 8 2014 <br />CERTIFICATION /TEST DATE: July 2, 2014 <br />Al. FACILITY A2. OWNER ENVIRONMENTAL HEAL <br />Name Quik Stop Market # 76 Name Quik Stop Markets, Inc. DEPARTMENT <br />Address 1030 S. Olive Avenue, Stockton, CA 95215 Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 Phone # 510-657-8500 <br />Contact Roger Batra Contact Debbie Markovich <br />A3. C U P A <br />INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to Indicate equipment inspected/serviced) <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />June 18, 2014 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Jeff Wong <br />❑ <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />In -Tank Gauging Probe <br />Phone # <br />916-373-1166 <br />B. <br />INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to Indicate equipment inspected/serviced) <br />61: TANKS <br />Tank #1 (Product): Gasoline - 87 <br />Tank #2 (Product): Gasoline - 91 <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794380-303 <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794380-303 <br />■ <br />Piping Sump/ Trench Sensor(s) <br />Model: 0794380-208 <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />■ <br />Mechanical Line Leak Detector <br />Model: FE Petro STP -MLD <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />Tank #3 (Product): <br />Tank #4 (Product): <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />; ❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />B2: <br />DISPENSERS/UDC's <br />Dispenser # : 1-2 <br />Dispenser # : 3-4 <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />■ <br />Shear Valves <br />■ <br />Shear Valves <br />■ <br />Dispenser Containment Float(s) and Chain(s) <br />■ <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Shear Valves <br />❑ <br />Shear Valves <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Shear Valves <br />❑ <br />Shear Valves <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced In accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />0* �% /, ��//!% WALTON <br />Signature: C^`^�C ENGINEERING, INC. <br />Technician I Cert #: Chris Kuykendall / B42243 8161927 Date: July 2, 2014 <br />