Laserfiche WebLink
MONIT40ING SYSTEM CERT1F4kAT1dMr-U=jVE[) <br />CERTIFICATION /TEST DATE: Jul 2, 2014 JUL <br />A1. FACILITY A2. OWNER ENVIRONMENTAL EAS <br />Name Quik StopMarket # 76 Name Quik StopMarkets, Inc. I I <br />Address 1030 S. Olive Avenue, Stockton, CA 95215 Address 4567 Enterprise Street, Frem 2,A ENT <br />Phone # 510-657-8500 Phone # 510-657-8500 <br />Contact Roger Batra Contact Debbie Markovich <br />D. RESULTS OF TESTING / SERVICING <br />Make / Model of Monitoring System: Gilbarco EMC <br />Software Version Installed: 327.04 <br />Complete the following checklist: <br />SN# 80850139005001 <br />In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Replaced the backup battery <br />in the EMC console. <br />Page 2 of 3 <br />■ Yes TO <br />No* <br />Is the audible alarm operational? <br />■ Yes <br />❑ No* <br />Is the visual alarm operational? <br />■ Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />■ Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />❑ Yes <br />■ Yes <br />■ Yes <br />❑ No* <br />■ N/A <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modems) <br />operational? <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a teak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (check all that apply) ❑ Sump/Trench sensors; [I Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? _ <br />❑ No* <br />❑ N/A <br />❑ No* <br />❑ Yes <br />❑ No* <br />■ N/A <br />❑ Yes * <br />■ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes' <br />■ No <br />Was any liquid found inside any secondary containment systems designed as dry systems? <br />(Check all that apply) El Product; El Water. If yes, describe causes in Section E, below. <br />■ Yes <br />❑ No* <br />Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable. <br />■ Yes <br />❑ No * <br />Is all monitoring equipment operational per manufacture <br />In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Replaced the backup battery <br />in the EMC console. <br />Page 2 of 3 <br />r's specifications? <br />In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Replaced the backup battery <br />in the EMC console. <br />Page 2 of 3 <br />