My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 9:07:22 AM
Creation date
6/3/2020 9:51:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
&..... <br /> �V A <br /> R-ROOT <br /> a <br /> THE KEY TO CALIFORNIA <br /> Veeder-Root's California Air Resources Product Components <br /> Board(CARB)certified In-Station <br /> Diagnostics(ISD)system provides the -Assist Vapor Flow Meter—Designed to F , <br /> most accurate vapor recovery detection withstand the harsh vapor recovery <br /> available in the industry environment found in systems with vapor <br /> vacuum pumps.It provides ISD with the I $ <br /> Veeder-Root's ISD system continuously volume of vapor recovered during vehicle TL <br /> monitors the vapor recovery equipment, refueling for continuous vapor collection <br /> maintains test records,provides test monitoring f ,_ <br /> reports,and generates warnings or a Balance Flow Meter —Designed for use <br /> alarms following equipment failure. in pressure sensitive balance systems to Vapor Flow[Meter <br /> maintain accuracy and minimize false ;; Al <br /> The Veeder-Root ISD system can be alarms,It provides iSD with the volume of <br /> added to any TIS-350 console.This vapor recovered during vehicle refueling for r <br /> provides you with a cost effective continuous vapor collection monitoring <br /> solution with the Veeder-Root quality <br /> and support that you expect. Y Vapor Pressure Sensor —Provides ISD with <br /> tank ullage pressure for vapor containment <br /> The Most Installed ISD Solution leakage and overpressure monitoring <br /> ®ISD Software Enhancement Module <br /> Starting September 2010,ISD is tt;i <br /> (SEM)— Ir <br /> required on all gasoline dispensing= Unlocks the ISD software in the ; <br /> TLS-350 to provide continuous vapor <br /> facilities with an annual throughput over <br /> recovery monitoring <br /> 6100,000 gallons. <br /> 0 I1IVMEM 2 Board —Provides memory Vapor Pressure Sensor <br /> Whether assist or balance vapor expansion necessary for ISD report storage <br /> recovery,over 90%of California <br /> customers have selected Veeder-Root's <br /> ISD system. New stations select the Benefits of the Veeder-Root ISD System <br /> Veeder-Root balance ISD solution due to Exceeds Compliance Requirements Cost Effective Solution <br /> simpler nozzle alatxn requirements. <br /> a GARB cenified with all approved •ISD OEM can be added to any <br /> Veeder-Roots ISD is the only certified hanging hardware,providing California TLS-350 console,leveraging existing <br /> solution that supports all vapor customers with the most options TIS-350 equipment <br /> processor configurations and all certified a Maximizes site uptime using Single 5 Minimizes initial equipment and <br /> vapor recovery nozzles. Dispenser Shutdown functionality <br /> installation costs <br /> Flexible shutdown solutions allows *Flexible ISD solution cenified with all 4 ISD Sensors can share wiring conduit <br /> customers to choose between STP Vapor Processor configurations with other Veeder-Root intrinsically <br /> shutdown,single dispenser shutdown or *CARB certified to meet all ISD performance safe(IS)sensors <br /> use both configurations. <br /> requirements as defined b <br /> q y CP201 o Simple installation,compatible with all <br /> including at least a 95%probability of Dispensers <br /> failure detection while operating at no more <br /> than a I%probability of false alanrns "Single Dispenser or STP Shutdown <br /> Continuous monitoring identifies failed 8 Wireless option available <br /> vapor recovery equipment during warranty 0 Veeder-Root warranty for one year from <br /> periods without expensive manual testing date of installation for all new ISD <br /> VEEDER-ROOT components <br />
The URL can be used to link to this page
Your browser does not support the video tag.