My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2300 - Underground Storage Tank Program
>
PR0231732
>
COMPLIANCE INFO_1999-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 4:09:15 PM
Creation date
6/3/2020 9:51:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2010
RECORD_ID
PR0231732
PE
2361
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231732_2000 STIMSON_1999-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 4 <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: x Piping Manufacturer ❑Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: x Pressure ❑Vacuum ❑ Hydrostatic <br /> ❑Other(Spec) <br /> OTestquipment Used: Mc Daniels 4"gauges Equipment Resolution: .025 r/s <br /> Piping Run#1 trans Piping Run#2 reel Piping Run# Piping Run#Material: Fiberglass Fiberglass <br /> Manufacturer: Smith Smith <br /> Piping Diameter: 4"x 3" 4"x 3" <br /> ti <br /> Length of Piping Run: 36' 24' <br /> Product Stored: Jp8 Jp8 <br /> Method and location of Test boot Test boot <br /> i ping-run isolation: <br /> Wait time between applying <br /> pressure/vacuum/water and 10 min 10 min <br /> starting test: <br /> Test Start Time: 11:45 10:30 <br /> Initial Reading(Rj): 5 lbs 51bs <br /> Test End Time: 12:45 11:30 <br /> Final Reading(RF): 5 lbs 5 lbs <br /> Test Duration: I hr 1 hr <br /> Change in Reading(RF-RI): 0 0 <br /> Pass/Fail Threshold or 0 0 <br /> Criteria <br /> I e ull�, x I'-as?s ❑Fail x Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.