My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2300 - Underground Storage Tank Program
>
PR0231732
>
COMPLIANCE INFO_1999-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 4:09:15 PM
Creation date
6/3/2020 9:51:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2010
RECORD_ID
PR0231732
PE
2361
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231732_2000 STIMSON_1999-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />-- <br />S. FILL RISER CONTAOMFNT RUMP TF.CTTNC- <br />Facility is Not Equipped With Fill Riser Containment Sumps~ `.4 v — <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer D Industry Standard ❑ Professional Engineer <br />0 Other (Speci& <br />Test Method Used: O Pressure <br />O Other (Specify) <br />❑ Vacuum <br />(✓�Hydrostatic <br />Equipment Resolution: <br />Fill Sump # <br />----------- <br />Test Equipment Used: <br />Fill Sump # <br />Sum Diameter: <br />Sump Depth: <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />Fill Sump # <br />Fill Sump # <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testing: <br />Portion of Sump Tested <br />Sump Material: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (RI): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -R,): <br />Pass/Fail Threshold or Criteria: <br />Test Result: 0 Pass ❑ Fail <br />Is there a sensor in the sump? O Yes ❑ No <br />Does the sensor alarm when either <br />product or water is detected? O Yes O No DNA <br />0 Pass ❑ Fail . <br />O Yes O No <br />O Yes O No DNA <br />❑ Pass ❑ Fail <br />0 Pass ❑ Fail <br />O Yes O No <br />O Yes O No <br />0 Yes O No O NA <br />0 Yes 0 No O NA <br />Was sensor removed for testing? O Yes O No DNA <br />Was sensor properly replaced and <br />verified functional after testing? ❑ Yes O No DNA <br />❑ Yes ❑ No ❑ NA <br />O Yes O No DNA <br />O Yes ❑ No 0 NA <br />O Yes O No O NA <br />O Yes O No O NA <br />O Yes O No DNA <br />Comments — (include information on repairs made prior 10.1esting, and recommended follow up fof failed tests) <br />