My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2300 - Underground Storage Tank Program
>
PR0231732
>
COMPLIANCE INFO_1999-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 4:09:15 PM
Creation date
6/3/2020 9:51:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2010
RECORD_ID
PR0231732
PE
2361
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231732_2000 STIMSON_1999-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />SWRCB, January 2002 Page of <br />t Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: <br />0 Tank Manufacturer X Industry Standard- NFPA 30 <br />0 Other (Spec) <br />0 Professional Engineer <br />Test Method Used: <br />0 Pressure X Vacuum <br />X Other (Specify) or acoustical mic UST 2001 <br />0 Hydrostatic <br />Test Equipment Used: UST 2001 or Mc Daniels / 3D test gauges — NIST <br />EEEENMNEN� <br />Tank # 1 Tank # <br />Equipment Resolution: +/- 0.25% fs <br />EM <br />Tank # Tank # <br />Is Tank Exempt From Testing?' <br />X No 0 Yes 0 No <br />0 Yes 0 No <br />0 Yes 0 No <br />Tank Capacity: <br />15000 <br />Tank Material: <br />Steel <br />Tank Manufacturer: <br />Trusco <br />Product Stored: <br />Jet fuel <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />9am <br />Initial Reading (Ri): <br />6.6" Hg <br />Test End Time: <br />10:50 am <br />Final Reading (RF): <br />6.6" Hg <br />Test Duration: <br />1 hour 50 min <br />Change in Reading (RF -RI): <br />0.0 <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />X Pass 0 Pass 0 Fail <br />0 Pass 0 Fail <br />® Pass 0 Fail <br />Was sensor removed for testing? <br />X Yes 0 No 0 NA 0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />XYes 0 No 0 NA 0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up or ailed tests) <br />t Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />