My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_1996-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:32:29 PM
Creation date
6/3/2020 9:52:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2006
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_1996-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />• <br />• • <br />ENVIROFLEX° RETRACTABLE PIPING SYSTEMS <br />Minimum burial depths shown in the above table are <br />acceptable if, and only if, the following conditions are met: <br />1. The ditch width is 2-1/2' or less. <br />2. The paved surfaces extend at least 2' on either side <br />of the ditch. <br />3. The fill material is clean sand or 1/8" to 3/4" pea <br />gravel. <br />4. Six inches of fill material is placed under the pipe as <br />bedding material. <br />Remaining backfill above the sand or pea gravel amounts <br />shown in the last column can be native soil if desired. <br />Multiple lines in the same ditch should be separated by a <br />minimum of 4" if special precautions are taken to insure <br />that backfill material is placed under and around the pipe. <br />In all cases there must never be a void of backfill under or <br />around the pipe. <br />The maximum allowable burial is 23' for burial in <br />moderately compacted soils which do not contain clay <br />and where the soil modulus is at least 1000 psi. <br />If you have any further questions, please contact your <br />local TCI representative. <br />AS REQUIRED FOR LISTING WITH UNDERWRITERS' LABORATORIES OF CANADA, ENVIROFLEX® DOUBLE-WALL PIPING SYSTEMS MUST <br />BE INSTALLED WHEN AMBIENT TEMPERATURE IS ABOVE 0°F. <br />e7' 2T —+-I — er +— 27' --+I <br />I El <br />e® 25 J 21 J 18 <br />MUST ALLOW MINIMUM 1 /8' SLOPE PER FOOT <br />PREPARING THE SITE <br />Step One— Layout <br />Determine the design layout. Remember to maintain a <br />3' minimum bend radius for all secondary piping. <br />A) Entering the dispenser <br />sumps from the same sides <br />maintains product uniformity. <br />B) By reversing product order <br />with each successive dispenser <br />less piping will be required for <br />most applications. <br />Step Two— Piping Trench <br />As shown above, compute the depth of the piping using a <br />minimum 1/8" of slope per foot of secondary pipe. The <br />total distance from the tanks to the furthest dispenser will <br />determine the depth of the tanks. This only applies for <br />below ground tanks. <br />Step Three <br />Thoroughly bed piping trench with a minimum of 6" of <br />approved backfill material (pea gravel, or sand). Make <br />sure all trenches are sloped with a minimum of 1/8" per <br />foot from the furthest dispenser towards the tank field. <br />Page 1 - Enviroflex Instructions <br />BURIAL SPECIFICATIONS <br />Minimum <br />Minimum Sand or <br />Pipe Size <br />Surface Condition Burial Depth <br />Pea Gravel Above Pipe <br />2" <br />Unpaved 17" <br />12" <br />(VP2501) <br />Paved, Minimum 4" Asphalt 12" <br />8" <br />Paved, Minimum 4" Concrete 9" <br />6" <br />4" <br />Unpaved 20" <br />14" <br />(Enviroflex®) <br />Paved, Minimum 4" Asphalt 14" <br />10" <br />Paved, Minimum 4" Concrete ill, <br />7" <br />Minimum burial depths shown in the above table are <br />acceptable if, and only if, the following conditions are met: <br />1. The ditch width is 2-1/2' or less. <br />2. The paved surfaces extend at least 2' on either side <br />of the ditch. <br />3. The fill material is clean sand or 1/8" to 3/4" pea <br />gravel. <br />4. Six inches of fill material is placed under the pipe as <br />bedding material. <br />Remaining backfill above the sand or pea gravel amounts <br />shown in the last column can be native soil if desired. <br />Multiple lines in the same ditch should be separated by a <br />minimum of 4" if special precautions are taken to insure <br />that backfill material is placed under and around the pipe. <br />In all cases there must never be a void of backfill under or <br />around the pipe. <br />The maximum allowable burial is 23' for burial in <br />moderately compacted soils which do not contain clay <br />and where the soil modulus is at least 1000 psi. <br />If you have any further questions, please contact your <br />local TCI representative. <br />AS REQUIRED FOR LISTING WITH UNDERWRITERS' LABORATORIES OF CANADA, ENVIROFLEX® DOUBLE-WALL PIPING SYSTEMS MUST <br />BE INSTALLED WHEN AMBIENT TEMPERATURE IS ABOVE 0°F. <br />e7' 2T —+-I — er +— 27' --+I <br />I El <br />e® 25 J 21 J 18 <br />MUST ALLOW MINIMUM 1 /8' SLOPE PER FOOT <br />PREPARING THE SITE <br />Step One— Layout <br />Determine the design layout. Remember to maintain a <br />3' minimum bend radius for all secondary piping. <br />A) Entering the dispenser <br />sumps from the same sides <br />maintains product uniformity. <br />B) By reversing product order <br />with each successive dispenser <br />less piping will be required for <br />most applications. <br />Step Two— Piping Trench <br />As shown above, compute the depth of the piping using a <br />minimum 1/8" of slope per foot of secondary pipe. The <br />total distance from the tanks to the furthest dispenser will <br />determine the depth of the tanks. This only applies for <br />below ground tanks. <br />Step Three <br />Thoroughly bed piping trench with a minimum of 6" of <br />approved backfill material (pea gravel, or sand). Make <br />sure all trenches are sloped with a minimum of 1/8" per <br />foot from the furthest dispenser towards the tank field. <br />Page 1 - Enviroflex Instructions <br />
The URL can be used to link to this page
Your browser does not support the video tag.