My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:40:58 PM
Creation date
6/3/2020 9:52:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd/unitiii.htmi <br /> CONTINUATION FORM Page: 4 of 4 <br /> OFFICIAL INSPECTION REPORT Date: 06/29/11 <br /> Facility Address: 3032 E. Waterloo Rd., Stockton Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> 27. The Dispenser#3/4 UDC sump sensor failed to shut down the 91-octane pump, the 91-octane STP <br /> sensor failed to shut down the 91-octane pump, and the diesel STP sensor could not be verified to shut <br /> down the diesel pump (but was noted to shutdown the 91-octane pump instead). The diesel and 91- <br /> octane lines do not meet the requirements for annual line tightness testing exemption. Annual line <br /> tightness testing is required unless the UST system is equipped with the following: <br /> 1. A continuous monitoring system that either activates an audible and visual alarm or stops the flow <br /> of product at the dispenser when it detects a leak <br /> 2. A monitoring system that shuts down the pump or stops the flow of product at the dispenser when <br /> it detects a leak <br /> 3. A monitoring system for piping other than that in UDC sumps (tank top sumps, transition vents, <br /> etc.) is failsafe and shuts down pump when a leak is detected <br /> Immediately schedule this test by properly licensed, trained, and certified contractor, and provide 48 <br /> hours notification to the EHD. A permit is required if the system had to be repaired, reprogrammed, or <br /> components replaced. If this could not be verified under EHD inspection within 7 days, additional <br /> enforcement action may be taken. <br /> NOTES <br /> Facility manager stated the diesel dispenser is down; therefore the pump could not be activated / <br /> authorized. <br /> 25. Annual monitoring system certification and leak detector testing was last performed on June 30, <br /> 2010 and was due by June 30, 2011. The sensor-out and fail-safe portion of the monitoring certification, <br /> and diesel line-leak detector could not be performed today. These tests are required once every 12 <br /> months. Immediately schedule these tests and provide 48 hours notification to the EHD. Please be <br /> aware that a follow up inspection will be charged at our current hourly rate. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by July 30, 2011. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS F CILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EH pecto Received By: Title: <br /> EHD23-02-OV RL0811CU CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.