My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
COMPLIANCE INFO_2002-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 3:20:02 PM
Creation date
6/3/2020 9:52:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2010
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231764_5611 E WATERLOO_2002-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer C Industry Standard ❑Professional Engineer <br /> 0 Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum 0 Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:TS STS Equipment Resolution: .000 <br /> Sump#87 Sump#91 Sump#DSL Sump# <br /> Sump Diameter: 42 42 42 <br /> Sump Depth: 58 58 58 <br /> Sump Material: FIBERGLASS FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Top of 14 14 14 <br /> Hi hest Pi in Penetration: <br /> Height from Tank Top to Lowest 14 14 l4 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: GOOD GOOD GOOD <br /> Portion of Sump Tested' 16 16 16 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No ❑NA 0 Yes ❑No DNA 0 Yes ❑No 0 NA C Yes ❑No 0 NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe 0 Yes 0 No ❑NA ❑Yes ❑No C NA ❑Yes 0 No ❑NA ❑Yes ❑No CNA <br /> shutdown?' <br /> Was fail-safe verified to be ❑Yes 0 No 0 NA 0 Yes ❑No ❑NA 0 Yes ❑No 0 NA ❑Yes C No ❑NA <br /> o erational?` <br /> Wait time between applying <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 1059 1133 1017 <br /> Initial Reading(RI): 2.9560 4.0593 4.0944 <br /> Test End Time: 1114 1148 1033 <br /> Final Reading(RF): 2.9555 4.0558 4.0948 <br /> Test Duration: 15 MIN 15 MIN 15 MIN <br /> Change in Reading(RF-RI): 1 0.0005 0.0035 0.0004 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 <br /> Test Result: YPass ❑Fail ❑ Pass 2rFail Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? XYes ❑No C NA VVes 0 No ❑NA //Yes ❑No ❑NA 0 Yes 11 No El NA <br /> Was sensor properly replaced and 5(Yes ❑No ❑NA (a"Yes ❑No ❑NA _Kes ❑No ❑NA ❑Yes ❑No CNA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to gfly of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.