My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
COMPLIANCE INFO_2002-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 3:20:02 PM
Creation date
6/3/2020 9:52:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2010
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231764_5611 E WATERLOO_2002-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT(UDQ TESTING <br /> Test Method Developed By: D UDC Manufacturer ❑Industry Standard 0 Professional Engineer <br /> 0 Other(Sped) <br /> Test Method Used: ❑Pressure ❑Vacuum 0 Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: TS STS Equipment Resolution:.0001" <br /> UDC#1-2 UDC#3-4 UDC#5-6 UDC#7-8 <br /> UDC Manufacturer: BRAVO BRAVO BRAVO BRAVO <br /> UDC Material: STEEL STEEL STEEL STEEL <br /> UDC Depth: 10 10 10 10 <br /> Height from UDC Bottom to Top 0 0 0 0 <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 0 0 0 0 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to GOOD GOOD GOOD GOOD <br /> testing: <br /> Portion of UDC Tested 3" 3" 3" 3" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes D No G NA D Yes D No ❑NA 11 Yes ❑No 11 NA ❑Yes 0 No ❑NA <br /> roduct and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- royes 0 No 0NA ❑Yes DNo ❑NA D Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> safe shutdown?`Was fail-safe verified to bees 0 No ❑NA ❑Yes ❑No DNA ❑Yes 0 No ❑NA 0 Yes ❑No ❑NA <br /> operational?` <br /> Wait time between applying NO-TEST NO-TEST <br /> pressure/vacuuL <br /> d <br /> startingtest <br /> Test Start Tim1224 1335 <br /> Initial Reading 0.8169 0.7354 <br /> Test End Time1239 1350 <br /> Final Reading 0.8170 0.7336 <br /> Test Duration: 15 MIN 15 MIN <br /> Change in Rea1): 0.0001 0.0018 <br /> Pass/Fail Threiteria: 0 0.002 0.002 <br /> Test Result: ❑ Pass ❑Fail ❑ Pass ❑Fail Pf Pass ❑Fail B'Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes ❑No ❑NA D Yes D No ❑NA !es D No 7XA ❑Yes 11NoWas sensor properly replaced and D Yes 0 No 0 NA D Yes ❑No ❑NA es ❑No AA 0 Yes ❑No NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> VISUAL LOSS AT TERMINATION BOOTS IN DISP 1-2, 3-4 <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to Iny of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />