My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
COMPLIANCE INFO_2002-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 3:20:02 PM
Creation date
6/3/2020 9:52:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2010
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231764_5611 E WATERLOO_2002-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ZTndustry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum 0"Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:TS STS Equipment Resolution:0.0001" <br /> UDC#1-2 UDC#3-4 UDC# UDC# <br /> UDC Manufacturer: BRAVO BRAVO <br /> UDC Material: STEEL STEEL <br /> UDC Depth: 10 10 <br /> Height from UDC Bottom to Top 0 0 <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 0 0 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to GOOD GOOD <br /> testing: <br /> Portion of UDC Tested 3" 3" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both !]Yes ❑No [INA ❑Yes ❑No [INA ❑Yes ❑No ❑NA ❑Yes ❑No [INA <br /> product and water)?* <br /> Turbine shutdown response time <br /> is system programmed for fail- ❑yes ❑No ❑NA Yes ❑No ❑NA ❑Yes ❑No [INA ❑Yes ❑No ❑NA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No [INA ❑Yes ❑No ❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 1459 1544 <br /> Initial Reading(Ri): 0.0623 0.0598 <br /> Test End Time: 1514 1559 <br /> Final Reading(RF): 0.0391 -0.0035 <br /> Test Duration: 15 MIN 15 MIN <br /> Change in Reading(RF-Ri): 0.0232 0.0633 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 <br /> Test Result: ❑ Pass ('Fail ❑ Pass ?fail ❑ Pass []Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes ❑No E?NA ❑Yes ❑No CNA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑yes ❑No <br /> verified functional after testing? CRNA ❑Yes ❑No CLIA ❑Yes ❑No [INA ❑Yes ❑No ❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.