2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2007-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 4:44:22 PM
Creation date
6/3/2020 9:53:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2011
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2007-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 5. <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC)TESTING <br /> Test Method Developed By: UDC Manufacturer �X Industry Standard ❑ Professional Engineer <br /> Other (Sped) <br /> Test Method Used: F] Pressure Vacuum Hydrostatic <br /> ❑ Other (Specify) <br /> Test Equipment Used: incon Equipment Resolution: +- .0020 <br /> UDC# 1-2 UDC# 1-2 UDC# 3-4 UDC# 3-4 <br /> UDC Manufacturer: f iberg f iberg f iberg f iberg <br /> UDC Material: f iberg f iberg f iberg f iberg <br /> UDC Depth: 24" 2 4" 2411 2411 <br /> Height from UDC Top to Top of 10" l0" 1011 l0" <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 411 411 411 411 <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: clean clean clean clean <br /> Portion of UDC Tested: 1 2"above 2"above 2"above 2 11 above <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes EIN�N ❑Yes�N�N ❑Yes❑N�N Yes❑NoXINA <br /> product and water)?* <br /> Turbine shutdown response time: <br /> Is system programmed for fail-safe ❑ ❑ ❑ ❑ ❑ F <br /> ❑ <br /> shutdown?* Yes N X N ❑Yes N X N Yes N X N Yes No X <br /> Was fail-safe verified to be ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ <br /> operational?* Yes N X N Yes N X N Yes N X N Yes No X <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15min 15min 15min 15min <br /> test: <br /> Test Start Time: 1 142 158 142 158 <br /> Initial Reading(RI 1 4.6375 4.6483 3.8828 3 .8775 <br /> Test End Time: 157 213 157 215 <br /> Final Reading(RF): 4.6483 4.6470 3 .8839 3 .8774 <br /> Test Duration: 15min 15min 15min 15min <br /> Change in Reading(R F-Ri ): +.0008 - .0012 +.0011 -.0001 <br /> Pass/Fail Threshold or Criteria: .0020 .0020 .0020 .0020 <br /> Wil <br /> SOMME= <br /> Was sensor removed for testing? X Yes❑NoONA MZ[:]No❑NA E]Yes❑N NA Yes[]No <br /> Was sensor properly replaced and r—__1 oYesaN�NA �Yes]Nc❑NA Yes�No�T <br /> verified functional after testing? <br /> Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer to-any-of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />