My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aug. 28. 2014 10: 14AM No. 4580 P. 5 <br /> Page 6 of 26 <br /> 5. SECONDARY PIPE TESMG <br /> Test Method Developed By: Q Piping Manufacturer Industry Standard n Professional Engineer <br /> 0 Other(Spmi)J) <br /> Test Method Used: 0 Pressure ❑vacuum C hydrostatic <br /> El Other(Specify) <br /> Test Equipment Used: See attached tating procedures Equipment Resolution: <br /> Piping Ran# Tp Piping Ran Piping Run# Piping Run# <br /> Piping Material: <br /> Piping <br /> Piping Manufacturer: <br /> F-i <br /> Piping Piping Diameter: <br /> Length of Piping Run: da.,f-k zge-, ZVO <br /> Product Stored: r 7 <br /> Method and location of <br /> M 2)in g-::ru RD.!i SE 02 11 ant i 20 n: <br /> Wait time between applying 30 minutes 30 minutes 30 minutes 30 minutes <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Reading(ki): S psi 'Psi psi psi <br /> Test End Time: 9 15 <br /> Final Reading(A*): psi 10—d psi psi <br /> Test Duration: 1 hour I hour I hour I hour <br /> Change in Reading(RF-n; 0 -0 <br /> Pass/Fail Threshold or 0100 0.00 0.00 0.00 <br /> Criteria: <br /> Comments-(Include information on repairs made prior to testa,and recommendedfollow-upforfaded tests) <br /> '"WEEME W WOMMOMW <br /> AUG 2 8 <br /> 2014 <br /> HFAIT-m nie vmmm <br />
The URL can be used to link to this page
Your browser does not support the video tag.