My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:02:36 PM
Creation date
6/3/2020 9:53:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2006-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
483
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. <br /> SAN JQAQUIN COUNTY ENVIRONMENTAL HEALTH'tDEIjART1ti NT <br /> 304 E.Weber Ave.,Third Floor Stockton,CA 95202-2708 O hdoe(209)468=3420 "> " <br /> Donna Heran,RE-H.S.,Director <br /> N i ONMENTAL I-IE .'TSI, <br /> SAN JbAQUIN COUNTY CERTIFIED UNIFIED PICOGRAM AGENCY. <br /> PERMIT TO OPERATE <br /> Program Permit Permit <br /> Record II? Number Program Code and Description Valid <br /> i `���i�n.y ■1 A��Wlil�l "�.II G,"6. .I��r�l <br /> PR0231866. 2300-UNDERGROUND S70RAQS TANK FACIWTY 1PU2006 To 12/31/2006 <br /> Underground.Storatle TankProclram: <br /> 6alifornla Health and Safety Code,_Dh 2Q,Chap_6_Zand Tikle23 California Code of Regulations Chap.76 <br /> -------------- <br /> ------------------------- ;- ------------------- <br /> System# Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection <br /> 4 3 2 186605155 PT0041620 8,000 DIESEL Active,billable DOUBLE V1IALLEU. ' Continuous Interstitial Monitoring <br /> •Ubdergrogdd Storage Tank Permif Conditions <br /> 1). .The Penif to,,bperate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to tri khain ilisompliance with these Permit Conditions <br /> Z), In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CC'R;lWe 23,t hsp.`16'and 18;as well as any conditions <br /> established by San Joaquin County, <br /> s).. if the Tank Operator(s)is different from the Tank Charter;`or if the Permit to Operate is issued to a person other than the owner or operator of the tante,tale Pea tittee shall ensure that both; <br /> ' the Tank Owner and tank Operator receive a copy of the permit. <br /> 4), Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved - <br /> -monitoring,response,and plot plans shall be maintained onsite with the permit. ' <br /> 3), The Permittee shall comply with the monitoring procedures referenced in this permit. <br /> 6),* <br /> The Permittee shall,perform testing and preventive maintenance on all leak detection monitoring equipment annuallq er itCore fioguetitly if,specified*the a Wpment manufacturer,and <br /> provide documentation of such servicing to this office. <br /> i 9)' In the event of a spill,leak,or other unauthorized release,the Permitee shall comply with the requirements of Title 23 Ute,C1isp:16 Art 5;Snd the approved Emergency Response Plan: <br /> , Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection fors p&iod.of at leasftfuee years$om the date the monitoring was <br /> performed. <br /> 9)."the EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change.- <br /> )p)' Upon any change in equipment,design or operation of the UST system(including change in tank contents ortsage),the Permit to Opi rate Wr1l:lie"Subject to review,modification or <br /> revocation. <' <br /> Construction.,repair and/or removal permits are required from the EHD prior to:any change,repair or removal of UST system equipment.. <br /> 12),'•`The Permittee shall submit an annual report documenting compliance with the UST Permit Conditions within 30 days of the date of the iss6attee•of ddspemptt.• <br /> 13) "This Permit tOt1'pslate;shall not be considered'permission to violate any laws,ordinances or statutes of any other Federal,State or I.00ad agency;' <br /> 14) A"Conditional"Pemrit may be revoked if corrections specified on the inspection report,are not completed by the date(Ej)indit attd , <br /> • <br /> "a <br /> PERMITS TO OPERATE are NOT TRANSFEWtE <br /> = and may be SUSPENDED or REVOKED for catil�e., <br /> g <br /> PERMIT(s)Valid only for: PACIFIC BELL ENVIRONMENTAL•M�'a,T <br /> DBA: ,PACAC BELL ; <br /> T$S FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> Regulated Facility: 'PACIFIC BELL Facility ID PA0603957 <br /> 124 W ELM ST <br /> AccountID AR0003569 <br /> LOpI GA. 95240 - Issued 2/3/2006 <br /> Bilting;Adtiress: ATTN. ; SBC ENVIRONMENTAL MGMT <br /> •PACIFIC BELL ENVIRONMENTAL MGT <br /> PO BOX 5095, RM 3E000 <br /> SAN RAMON CA 94583-0995 <br /> .. t <br />
The URL can be used to link to this page
Your browser does not support the video tag.