PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2006-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
483
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page _2_ of_6_ <br />Test Method Developed By: <br />4. TANK ANNULAR TESTING <br />® Tank Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure 0 Vacuum ❑ Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: 2 INCH ANALOG GAUGE <br />Bill Tank #DIESEL Tank # <br />ME <br />Is Tank Exempt From Testing?' ❑ Yes ® No ❑ Yes ❑ No <br />Equipment Resolution: <br />Tank # Tank # <br />❑ Yes ❑ No ❑ Yes 0 No <br />Tank Capacity: <br />8,000 GALLON <br />Tank Material: <br />FIBERSTEEL <br />Tank Manufacturer: <br />MODERN <br />WELDING <br />Product Stored: <br />RED DIESEL <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 MINUTES <br />Test Start Time: <br />9:15 <br />Initial Reading (RI): <br />7" HG <br />Test End Time: <br />10:15 <br />Final Reading (RF): <br />T' HG <br />Test Duration: <br />1 HOUR <br />Change in Reading (RF -R): <br />0" HG <br />Pass/Fail Threshold or Criteria: <br />0" HG <br />Test Result: <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />0 e ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and ® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Diesel Tank (41214) Annular passed the tank manufacturer recommended yearly test. No repairs <br />are needed at present time. <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />tPetina fr-A1;fnrnia r^AP nfRPanlatinne Titles 72 CP(`tlnn')ATUWANI <br />