My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> MR 2 <br /> Software Version Installed: 122.00 <br /> 14, <br /> Complete the following checklist: <br /> F10- Yes I F No* I Is the audible alarm operational? <br /> F" Yes F N o* Is the visual alarm operational? <br /> .......... <br /> Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> P Yes No* <br /> ..........�, ......... <br /> ...........= . ........NNrNN . ....... <br /> Were all sensors installed at lowestpoint of secondary containment and positioned so that other equipment <br /> R Yes 11 f No* <br /> Swill not interfere with their <br /> 0000�1 MWKIMW�11 <br /> Yes7 No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> operational? <br /> F N/A <br /> Yes N o* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> N/A containment monitoring system detects a leak,fails to operate,or is electrically disconnected?If yes:which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> F Sump/Trench Sensors; F Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to I eaks and sensor failure/disconnection? <br /> F Yes; r- No <br /> .. ............... <br /> ............. <br /> Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> i <br /> mechanical overfill prevention valve is installed),is the overfi ll warning alarm visible and audible at the <br /> pi N/A <br /> tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alann trigger? <br /> Yes No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment <br /> 'I <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> f Yes* ry No pp <br /> liquid found inside any secondary containment systems designed as dry systems? (Check all at <br /> y) F Product; F Water.If yes,describe causes in Section E,below. <br /> --—------------------------- <br /> F Yes F No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ......... <br /> T <br /> Yes No* Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Additional sensors from page 1. <br /> L-4 Generator Floor 7943 80-208/n/a Certified. <br /> L-5 Fire Box 794380-208/730237 Certified.. <br /> An overfill prevention valve is installed in the drop tube. <br />
The URL can be used to link to this page
Your browser does not support the video tag.