Laserfiche WebLink
D. Results of Testing/Servicing <br /> MR 2 <br /> Software Version Installed: 122.00 <br /> 14, <br /> Complete the following checklist: <br /> F10- Yes I F No* I Is the audible alarm operational? <br /> F" Yes F N o* Is the visual alarm operational? <br /> .......... <br /> Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> P Yes No* <br /> ..........�, ......... <br /> ...........= . ........NNrNN . ....... <br /> Were all sensors installed at lowestpoint of secondary containment and positioned so that other equipment <br /> R Yes 11 f No* <br /> Swill not interfere with their <br /> 0000�1 MWKIMW�11 <br /> Yes7 No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> operational? <br /> F N/A <br /> Yes N o* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> N/A containment monitoring system detects a leak,fails to operate,or is electrically disconnected?If yes:which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> F Sump/Trench Sensors; F Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to I eaks and sensor failure/disconnection? <br /> F Yes; r- No <br /> .. ............... <br /> ............. <br /> Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> i <br /> mechanical overfill prevention valve is installed),is the overfi ll warning alarm visible and audible at the <br /> pi N/A <br /> tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alann trigger? <br /> Yes No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment <br /> 'I <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> f Yes* ry No pp <br /> liquid found inside any secondary containment systems designed as dry systems? (Check all at <br /> y) F Product; F Water.If yes,describe causes in Section E,below. <br /> --—------------------------- <br /> F Yes F No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ......... <br /> T <br /> Yes No* Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Additional sensors from page 1. <br /> L-4 Generator Floor 7943 80-208/n/a Certified. <br /> L-5 Fire Box 794380-208/730237 Certified.. <br /> An overfill prevention valve is installed in the drop tube. <br />