My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: ancon TS-STS Equipment Resolution: .0006 <br /> UE020 1001 <br /> Sump Diameter: 40" <br /> Sump Depth: 45" <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of ii <br /> 14" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 14" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: good <br /> Portion of Sump Tested' 2"above high pen <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No ®NA [:]Yes❑No❑NA ❑Yes❑No ❑NA ❑Yes[-]NO❑NA <br /> product and water?` <br /> Turbine shutdown response time N/A <br /> Is system programmed for fail-safe ❑Yes [—]No ❑X NA <br /> shutdown?* ❑Yes[--]No❑NA ❑Yes❑No DNA ❑Yes❑No❑NA <br /> Was fail-safe verified to be ❑Yes ❑No ❑X NA <br /> ❑Yes[:]NO❑NA ❑Yes[-]NO❑NA ❑Yes❑No[:]NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15min <br /> test: <br /> Test Start Time: 10:11 am 10:27am <br /> Initial Reading(Ri): 3.8799 3.8796 <br /> Test End Time: 10:27am 10:42am <br /> Final Reading(RF): 3.8798 3.8796 <br /> Test Duration: 16min 15min <br /> Change in Reading(RF-RI): .0001 0 <br /> Pass/Fail Threshold or Criteria: .002 .002 <br /> Test Result: 191 Pass ❑Fait ❑Pass ❑Fail ❑Pass ❑Fai! ❑Pass ❑Fail <br /> Was sensor removed for testing? ❑X Yes ❑No ❑NA ❑Yes❑No[:]NA ❑Yes[:]No❑NA ❑Yes❑No❑NA <br /> Was sensor properly replaced and ❑Yes ❑X No [:]NA <br /> verified functional after testing? Dyes❑No❑NA Dyes❑No❑NA ❑Yes❑No❑NA <br /> Comments—(include in on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Sensor was removed but not tested, reinstalled to lowest point. � <br /> OCT 3 0 2017 <br /> ENV1F'10NN4ENTA,L HEALTH <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to way of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.