My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix V1 <br /> (Copies of Monitoring System Certification form and LIST Monitoring Plot Plan available atca.gov .) <br /> MONITORING SYSTEM CERTIFICATION MAR 15 2016 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Co de;Chapter 16,Division 3, Title 23,California Code ofRegulationENVIRONMENTAL <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank-system owner/operator. The <br /> ov,ner/operator must submit a copy o f this form to the local agency regulating LIST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pacific Bell Telephone Co dba ATT California Facility ID: UE020 <br /> Site Address: 124 W. Elm St. City: Lodi Zip: 95240 <br /> Facility Contact Person: Thuy Tran Contact Phone No.: 209-474-4022 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Plus Date of Testing/Servicing: 03-01-2016 <br /> B. Inventory of Equipment Tested/Certi tied <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: UE0200001 1! Tank ID: UE020A003 <br /> In ❑In-Tank Gauging Probe. Model: <br /> PFX -Tank Gauging Probe. Model: 847390-107/439514 <br /> 1z X Annular Space or Vault Sensor. Model: 794390-420/441672I Annular Space or Vault Sensor. Model: 794380-344 844409 Fx <br /> JIN Piping Sump/Trench Sensor(s). Model: 794380-208/685112 ❑Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Serisor(s). Model: 794380-208/657586 1❑Fill Sump S sor(s). Model: <br /> Ej <br /> F-1 Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: ii <br /> Electronic Line Leak Detector. Model F❑-1'IElectronic Line Leak Detector. Model:F❑1 <br /> FX� Tank Overfill/High-Level Sensor. Model: 790091-001 <br /> Tank Overfill/High-Level Sensor. Model: <br /> 1 <br /> Other(specify equipment type and model in Section E on Page 2).1FX Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID- Tank ID: <br /> II❑ In-Tank Gauging Probe. Model: ❑In-Tank G augging Probe. Model: <br /> H❑ Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> ij <br /> Piping Sump/Trench Sensor(s). Model: <br /> I E ❑Piping Sump/Trench Sensor(s). Model: <br /> I F-1 Fill Sunip Sensor(,). Model: ❑Fill Sump Sensor(s). Model: <br /> ppppl <br /> 1❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> IF-1 Electronic L ine Leak Detector, Model: Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/Fligh-Level Sensor. Model: 11❑Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on Page 2). 110 Other(speci6,equipment type and model in Section E on Page 2). <br /> S-_-----------_------ <br /> 'T...... <br /> Dispenser ID: Dispenser IDii I: <br /> Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ii <br /> Shear Valve(s). ❑Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). <br /> ❑Dispenser Containment Float(s)and Ch ain(s). <br /> ...........� -------.............I'll, <br /> ............ <br /> I Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: i❑Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shea,Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s)€ ❑Dispenser Containment Float(s)and Chain(s). <br /> ........ <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser set at the facility. <br /> C, Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and <br /> a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports,I have also attached a copy of <br /> the report;(check all tha t apply) : M�I <br /> I System set-up Z Alarm history report <br /> Technician Name(print): John Cascio Signature: _ �Wa &dda <br /> Certification No.: B35337 License. No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br /> Testing Company Address: 2131 SOUTH DUPONT DRIVE,ANAHEIM,CA92806 Date of Testing/Servicing: 03-01-2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.