COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D.Results of Testing/Servicing <br /> R 15 2016 <br /> Software Version Installed: 122.00 <br /> ENVIRONMENTAL <br /> Complete the following checklist <br /> Yes ❑No* 'Is the audible alarm operational <br /> ❑X Yes ❑ No* FIs the visual alarm operational? <br /> ._.._ <br /> ❑X Yes ❑No* 1 Were all sensors visually inspected, functionally tested and confirmed operational? (i <br /> X Yes * 71 W11 not linterfe s insth ted t lowest oint of secondary cont _.. , <br /> ..... _ _ <br /> ❑ ❑No p ainment and positioned so that other equipment <br /> roper o ration? <br /> 61amnM r <br /> NYes M No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) j <br /> N/A operational? 9 <br /> ❑ Yes ❑No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary j <br /> i <br /> QX NIA containment monitoring system detects a leak,fails to operate,or is electrically disconnected'?dyes:which <br /> ;sensors initiate positive shut-down?(Check all that apply) <br /> 1 <br /> ❑SumplTrench Sensors; El Dispenser Containment Sensors. Didyou confirm positive shut-down � <br /> !,due to l eaks and sensor failure/disconnection? <br /> ❑Yes, ❑No. <br /> ❑ Yes ' ❑No* Fortank systems that utilize themonitoring system as the primary tank overfill warning device(i.e.no <br /> ;,mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the <br /> 3 Q N/A tank fill point(s)and operating properly?If so, at what percent of tank capacity does the alarm trigger? <br /> j % <br /> QYes* 3' ® No w'as any monitoring equipment replaced?If yes,identify specific sensors,probes, or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section F,,below. <br /> i Was liquid found inside n secondary containments stems designed as dry systems (Check all <br /> that 0 No i; <br /> 1 apply) ❑Product, ❑Water.If yes describe causes in Section E below. <br /> ® Yes ❑No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> _ 1 <br /> ❑ ���X <br /> N ; Is all monitoring equipment operational per manufacturer's specifications? <br /> �1 <br /> *In Section E below,describe how and when these d eficiencies were or will be corrected <br /> E. Comments: <br /> Other Sensors from Page 1: <br /> L4:Generator Room Floor Sensor-794380-208/N/A-Certified <br /> L5: Fire Box Sensor-794380-208/730237-Certified <br /> An Overfill Prevention Valve is Located in the Drop Tube <br /> Replaced TLS backup battery prior to Certification <br />