My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 4:21:17 PM
Creation date
6/3/2020 9:53:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231867_345 N SAN JOAQUIN_2010-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin un$ <br /> OPQ'U�" Environmental Health Department DIRECTOR <br /> = � Donna Heran,REHS <br /> i 1868 East Hazelton Avenue <br /> PROGRAM COORDINATORS <br /> Stockton, California 95205®6232 Robert McClellon,REHS <br /> • Jeff Carruesco,REHS,RDI <br /> �q •..�. "'�P Website: .Sjgov.org/ehd Kasey Foley,REHS <br /> �r F o Eta <br /> Phone: (209)468-3420 Linda Turkatte,REHS <br /> September 17, 2012 Fax.: (209)464-0138 <br /> Chris Brown <br /> Stantec Architecture, Inc. <br /> 1383 N. McDowell Blvd., Suite 250 <br /> Petaluma, CA 94954 <br /> Re: AT&T (UE042) SR0065204 <br /> 345 N. San Joaquin St., Stockton <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the application for a permit dated June 22, 2012 and all the subsequent revisions and <br /> addendum up to August 6, 2012 to retrofit the underground storage tank (UST) system at the <br /> above noted address with the following: <br /> a. Replace all single-walled supply and return piping in the basement (a vault) and <br /> aboveground piping connected to the two generators on the roof with double- <br /> walled piping, <br /> b. Drain residual fuel from sections of piping where fuel cannot be drained back into <br /> UST by gravity into drums for approximately one hour, and temporarily secure <br /> the drums within the basement of the facility for off-site disposal <br /> C. Remove, triple-rinse, and dispose approximately 1,000 feet of fuel piping at the <br /> facility, <br /> d. Triple-rinse and abandon in place approximately 120 feet of piping within an <br /> inaccessible piping chase, <br /> e. Temporarily secure rinsate and any spent absorbent material within the <br /> basement of the facility-for off-site disposal <br /> f. Install new transition box on piping outside the building and,a Veeder Root 208 <br /> liquid sensor at the lowest point of the box, <br /> g. Install new fuel and return piping with secondary containment to replace the <br /> removed piping, <br /> h. Separate the vent and return lines so the two are no longer combined with the <br /> return line. Breaking concrete on the sidewalk and a new penetration into the <br /> fill sump are required for the new dedicated vent line. <br /> i. Install new Veeder Root firmware upgrade and cold start the monitoring system. <br /> The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br />
The URL can be used to link to this page
Your browser does not support the video tag.