EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:39:52 AM
Creation date
6/3/2020 9:54:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
405
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for DINO MART as of January04, 2018. <br /> Open violations from April 03, 2017 inspection <br /> Violation#101 -No permit to operate. <br /> A permit to operate the UST system has not been issued. No person may own or operate an UST unless a permit <br /> for its operation has been issued by the local agency to the owner or operator of the UST system. Immediately <br /> obtain a permit to operate a UST system from the Environmental Health Department(EHD). An "Operating without <br /> a Permit" penalty applies. <br /> Fees for the annual permit to operate the UST system have not been paid. No person may own or operate an UST <br /> unless a permit for its operation has been issued by the local agency to the owner or operator of the UST system. <br /> Immediately contact the EHD accounting office to make arrangements for payment to obtain a permit to operate a <br /> UST system. <br /> Violation#104-UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for TA0508418 (premium unleaded), TA0508419 (diesel), and TA0508420 (regular <br /> unleaded) are not current in CERS. Beneath Tank Construction, under Overfill Protection, change"Yes"to"No" for <br /> Audible/Visual Alarms. Beneath Vent, Vapor Recovery(VR)and Riser/Fill Pipe Piping Construction, complete <br /> sections titled: Vent Primary Containment, Vapor Recovery Primary Containment[not applicable for TA0508419 <br /> (diesel)], Riser Pipe Primary Containment. Beneath Fill Components Installed, change"No"to"Yes" for Striker <br /> Plate/Bottom Portector. Any change of information must be updated in CERS within 30 days of the changes. <br /> Immediately log into CERS, update the required information, and submit for review by the EHD. <br /> Violation#105-Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For TA0508418 (premium unleaded), <br /> TA0508419 (diesel) and TA0508420 (regular unleaded), beneath Tank Monitoring is Performed Using the Following <br /> Method(s), change"Yes" to"No"for Automatic Tank Gauging For TA0508418 (premium unleaded) change"Yeg' <br /> to"No"for Pipeline Integrity Testing; and beneath Training, change"No" to"Yeg' for Designated Operator Training. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> Open violations from March 09, 2017 inspection <br /> Violation#103-Current financial responsibility documents not submitted. <br /> Current financial responsibility documents have not been submitted to the EHD, the submitted documentation is <br /> lacking a signature of witness or a notary. Current financial responsibility documents are required to be submitted <br /> annually. Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, <br /> and upload the required documents. <br /> Violation#120 -Failed to submit UST Certification of Installation/Modification. <br /> The diesel underground fiberglass fitting located adjacent to UDC 3/4 was replaced under permit number <br /> SR0072496 and the UST Certification of Installation/Modification has not been submitted. This certification is <br /> required to be submitted within 30 days of completion of work to the California Environmental Reporting System <br /> (CERS). Immediately log into CERS, complete the required information, and submit for review by the EHD. <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.