COMPLIANCE INFO_2007-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKHEED
>
1941
>
2300 - Underground Storage Tank Program
>
PR0231891
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 3:00:31 PM
Creation date
6/3/2020 9:54:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231891
PE
2361
FACILITY_ID
FA0003674
FACILITY_NAME
BANK OF STKN AIRPORT HANGAR #3
STREET_NUMBER
1941
Direction
E
STREET_NAME
LOCKHEED
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
1941 E LOCKHEED CT
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231891_1941 E LOCKHEED_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />SWRCB, January 2002 Page of <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. f California Code of Regulations, Title 23, Section 2637(a)(6)) <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: <br />x Tank Manufacturer 0 Industry Standard D Professional Engineer <br />0 Other (.Sped) <br />Test Method Used: <br />0 Pressure <br />LI Other (Spec) <br />x Vacuum <br />0 Hydrostatic <br />Test Equipment Used: Dwyer Manometer <br />Equipment Resolution: +/- 2% <br />Tank # t <br />EENMIFAIMMIKEME <br />Tank# <br />Tank # <br />Tank# <br />Is Tank Exempt From Testing?' <br />0 Yes x No <br />0 Yes 0 No <br />t1 Yes U No <br />0 Yes 0 No <br />Tank Capacity: <br />12,000 <br />Tank Material: <br />Fiberglass <br />Tank Manufacturer: <br />Product Stored: <br />Jet A <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 min <br />30 min <br />30 min <br />30 min <br />Test Start Time: <br />9:45 <br />Initial Reading (RO: <br />6.05 <br />Test End Time: <br />10:45 <br />Final Reading (RF): <br />6.03 <br />Test Duration: <br />1 hour <br />1 hour <br />1 hour <br />I hour <br />Change in Reading (RF-RO: <br />A2 <br />Pass/Fail Threshold or Criteria: <br />No less than I" <br />No less than 1" <br />No less than I" <br />No less than I" <br />Test Result: <br />x Pass 0 Fail <br />0 Pass 0 Fail <br />❑ Pass 0 Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />x Yes 0 No 0 NA <br />x Yes ❑ No 0 NA <br />Was sensor properly replaced and x yes D No DNA x Yes 0 No 0 NA x Yes D No 0 NA x Yes 0 No 0 NA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. f California Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.