My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 1:45:39 PM
Creation date
6/3/2020 9:54:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_1998-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UCSB04N-SS#2611194 Page 5 of 7 <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: ❑UDC Manufacturer E Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum E Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: INCON TS-STS TEST UNIT Equipment Resolution: <br /> UDC#1-2 UDC#3-4 UDC#5-6 UDC#7-8 <br /> UDC Manufacturer: ENVIRON ENVIRON ENRIVON ENVIRON <br /> UDC Material: FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS <br /> UDC Depth: 24" 24" 24" 24" <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: 7 ''/2" 8" 8" 8" <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: 8" 6" 6" 6" <br /> Condition of UDC prior to <br /> testing: WATER FILLED GOOD GOOD GOOD <br /> Portion of UDC Tested 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> PIPING PENETRATION PIPING PENETRATION PIPING PENETRATION PIPING PENETRATION <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both YES YES YES YES <br /> product and water)? <br /> Turbine shutdown response time NA NA NA NA <br /> Is system programmed for fail- E Yes ❑No ❑NA N Yes ❑No ❑NA E Yes ❑No ❑NA E Yes ❑No ❑NA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes N No ❑NA ❑Yes N No ❑NA ❑Yes E No ❑NA ❑Yes N No ❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 MINUTES 15 MINUTES 15 MINUTES 15 MINUTES <br /> starting test <br /> Test Start Time: 1:45 2:01 1:45 2:01 1:45 2:01 2:33 2:49 <br /> Initial Reading(RI): 6.516 6.516 6.547 6.542 6.793 6.785 6.646 6.641 <br /> Test End Time: 2:00 2:16 2:00 2:16 2:00 2:16 2:48 3:04 <br /> Final Reading(RF): 6.516 6.516 6.543 6.538 6.789 6.777 6.642 6.638 <br /> Test Duration: 15 MIN 15 MIN 15 MIN 15 MIN 15 MIN 15 MIN 15 MIN 15 MIN <br /> Change in Reading(RF-RI): 0.000 0.000 -0.004 -0.004 -0.004 -0.008 -0.004 -0.003 <br /> Pass/Fail Threshold or Criteria: -0.002 -0.002 -0.002 -0.002 -0.002 -0.002 -0.002 70.002 <br /> Test Result: N Pass ❑Fail ❑ Pass [IPass a. ❑ Pass <br /> Was sensor removed for testing? N Yes ❑No ❑NA N Yes ❑No ❑NA N Yes ❑No ❑NA E Yes ❑No ;SIA <br /> Was sensor properly replaced and N Yes ❑No ❑NA N Yes ❑No ❑NA N Yes ❑No ❑NA E Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.