My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 1:45:39 PM
Creation date
6/3/2020 9:54:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_1998-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'e <br /> UCSB04N—SS#2611194 Page 6 of 7 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: INCON TS-STS TEST UNIT Equipment Resolution: <br /> Fill Sump#87 Fill Sump#89 Fill Sump#91 Fill Sump# <br /> Sump Diameter: NA NA NA <br /> Sump Depth: NA NA NA <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: NA NA NA <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: NA NA NA <br /> Condition of sump prior to <br /> testing: NA NA NA <br /> Portion of Sump Tested N NA NA <br /> Sump Material: NA NA NA <br /> Wait time between applying <br /> pressure/vacuum/water and NA NA NA <br /> starting test: <br /> Test Start Time: NA NA NA NA NA NA <br /> Initial Reading(RI): NA NA NA NA NA NA <br /> Test End Time: NA NA NA NA NA NA <br /> Final Reading(RF): NA NA NA NA NA NA <br /> Test Duration: NA NA NA NA NA NA <br /> Change in Reading(RF-RI): NA NA NA NA NA NA <br /> Pass/Fail Threshold or Criteria: NA NA NA NA NA NA <br /> Test Resrl ._ ❑ Pass ❑Fail ❑ Pass ❑Fail ❑"Pass 0" ail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? ®Yes ❑No ®Yes ❑No ®Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ®Yes ❑No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and O yes ❑No ❑NA N Yes ❑No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> FACILITY IS NOT EQUIPPED WITH FILL RISER SUMPS. <br />