My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 1:53:27 PM
Creation date
6/3/2020 9:54:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_2005-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
381
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Tesfing/Servidn,,; <br /> Soil-ware Version Installed: <br /> Complete the following checklist: <br /> La-'Ve-s Q No* Is the audible alann operational? <br /> es _.L3 No* Is the visual alarm operational? <br /> M es Q No*- Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> Er"Ves U No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> -not interfere with their proper operation? <br /> Ll No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> El--N7X--, operational? <br /> IYes U No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> U N/A monitoring system detects a leak, fails to opera't9 -is electrically disconnected? If yes: which sensors initiate <br /> �or <br /> positive shut-down? (Check all that apply) M-Sump/Trench Sensors; Q Dispenser Conoinment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? UYes; U No. <br /> — <br /> Q Yes Ll For tank systems that utilize the monitoring system as. the primary tank overfill warning device (i.e. no <br /> N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? — % <br /> L3 Yes* Q14o Was any monitoring equipment replaced? If yes, identify specific sensors,probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> E3 Yes* 0-go- Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) LJ <br /> Product; U Water. If yes,describe causes in Section E,below. <br /> LI-Ves LJ No*-- Was monitoring system set7up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> Ll Yes :9=0*- fs all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Th P L_ C_&Vi e c, rlc> A"TC) 'j- _1_0 <br /> QQ <br /> OJ <br /> 1r4 <br /> Page of 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.