Laserfiche WebLink
Plan Check Correction List: This is revised from the original correction <br /> notice dated 10/24/2012. David, there is quite a lot of information <br /> missing or inaccurate. <br /> Architectural: <br /> 1. Minor discrepancy on sheet A3.1 South elevation, existing roof overhang not <br /> shown. <br /> 2. In the converted garage area, are there remediation measures being taken to level <br /> the sloped floor? <br /> 3. Planning does not allow rooftop equipment to be visible from the public way in <br /> normal circumstances. Show locations and weight of any new rooftop equipment. <br /> 4. A new trash enclosure is shown on A1.1 but is not accompanied by plans or <br /> structural calculations. Provide. Note that Planning has height and roofing <br /> requirements I think, also, the configuration should be confirmed with Tracy <br /> Delta Disposal to assure the trucks can make use of the designed facility. <br /> 5. No information provided for exterior wall finish or moisture protection of <br /> structural members in walls. <br /> 6. Detail generic anchorage and construction method top and bottom for new interior <br /> walls. <br /> 7. Provide cutsheets and installation instructions for equipment that would be <br /> permanently installed. <br /> 8. Remove irrelevant data and notes. <br /> Structural: <br /> 1. You indicated that there would be changes to the structural driven by a change to <br /> the back of the store. <br /> 2. Sheet S 1.0 makes continual references to the UBC, sections and Tables of that <br /> code that became obsolete in January of 2008. Please review and revise to current <br /> codes, tables, section references for the 2010 CA Building Codes which are based <br /> on the 2009 International Building Code with California amendments. 2nd pass <br /> will not be accepted with these obsolete references. <br /> 3. Note 1, Detail 1 on sheet 51.0, and Note 1 on the shear wall schedule directs me <br /> to see plans and framing schedules for size and location of hold-downs, that <br /> information is not provided. Revise plans to show the required information <br /> consistent with the engineering design submitted. 2nd pass will not be accepted <br /> without this basic data in the normal format. Post location and sizes are also <br /> omitted. <br /> 4. Detail 12 on sheet S2.1 indicates a different anchor bolt depth than note 6 on sheet <br /> S 1.0. Coordinate. <br /> 5. Orientation is not correct on engineering calcs.NS/EW reversed I believe. <br /> 6. Provide plans and calculations for the new trash enclosure that is shown.on A1.1. <br />