Laserfiche WebLink
7. Foundation plans do not indicate continuous foundation under new shear walls. <br /> See 52.1. <br /> 8. Provide Simpson cutsheets for the shearwalls to be used along with anchor bolt <br /> length and foundation requirements. Current plans do not give enough (or any) <br /> information about interior footing size, depth for either of the interior footings <br /> required. <br /> 9. Please remove all irrelevant data and notes. <br /> Electrical/Mechanical/Plumbing: <br /> 1. Show modifications driven by relocation of the EVR system, routing of electrical, <br /> plumbing, fire separation, location etc. Insufficient data to assess code <br /> compliance. <br /> 2. Show location, anchorage, penetration detail and supporting equipment <br /> supporting the new walk-in cooler and freezer. Insufficient data to assess code <br /> compliance. Rooftop mounted equipment may not be visible from any public <br /> right of way and ground mounted equipment may need review by Planning for <br /> appearance factors. <br /> 3. Please be aware that a dishwasher, if installed, must have a type II hood or <br /> approved steam and heat removal system acceptable to the authority having <br /> jurisdiction. A recent "Alternate method and material submittal involving an <br /> ECOLAB dishwasher utilizing a "VaporVent" system was recently approved and <br /> if desired, may suit your needs if a dishwasher is desired.. Reference note 5 on <br /> P2.1. <br /> 4. Provide water hammer arresters where quick acting water valves are used. <br /> 5. Provide a detail showing required installation details for recirculating hot water <br /> systems as noted in the 2008 Building Energy Efficiency Standards section 113( <br /> c) 5, items A through F. <br /> 6. alb switching required in the store. <br /> 7. This building requires two exits and therefore requires emergency lighting under <br /> 90 minute battery power required with appropriate provisions of section 1006 of <br /> the 2010 CA Building Code. <br /> 8. Indicate location of emergency disconnect button for pumps. <br /> 9. Provide a calculation demonstrating sufficient outside air ventilation for the <br /> facility. <br /> 10. The plumbing code requires self-closing or self-closing metered faucets for <br /> lavatories intended to serve the transient public such as in service stations. See <br /> 2010 CA Plumbing Code section 402.4, these faucets must also meet <br /> accessibility requirements of section 111513.4.3 item 1. <br /> 11. Pressure temperature relief valve drainage tube to be routed outside the building <br /> per section 608.5 of the 2010 CA Plumbing Code. <br /> 12. Sheet A0.1 refers to sprinkler modification requirements and indicates non- <br /> sprinklered building. Coordinate <br /> 13. How is condensation from Refrigerator or Freezer being handled, I see no <br /> plumbing provisions for it. <br /> 14. Is all the electrical comprehended for the refrigeration, AC, Heating. I see fan <br /> coils in the refrigeration units but no compressors. Makes me wonder if all <br /> equipment is being comprehended. <br />