My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_JULY 2012-OCTOBER 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_JULY 2012-OCTOBER 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2024 1:51:29 PM
Creation date
6/3/2020 9:54:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JULY 2012-OCTOBER 2013
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_JULY 2012-OCTOBER 2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
491
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Owner - SSR Group acility 2375 North Trac Blvd, Trac Inspection Jul 5, 2012 <br />Name: ( p Inc)) Address: y y Date: <br />VIOLATIONS <br /># C1 C2 M Code Section HSC = CA Health and Safet Code; CFR =Code of Federal Re ulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non.�re" r�rrzes% i li con " <br />702 CCR 2643(e) Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 CCR 2643(d) Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />=x <br />" ``� �ther,Vtalatlons <br />999 X Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST Inspection: Routine only. No testing of the annual Monitoring System Certification was performed. <br />Facility has no UST operator since December 2010 and has been monitored daily since December 22, <br />2010 until June 30, 2012 by Savemart Management. Temporary closure procedures were not <br />performed. SSR Group Inc lease agreement starts July 1, 2012. <br />104. Financial responsibility documents have not been submitted to the EHD. No financial responsibility <br />document received at this site for 2010, 2011 and 2012 year. Last financial responsibility document <br />received was from August 2009 from the previous operator who was evicted from the facility in <br />December 2010. Current financial responsibility documents are required to be submitted annually. <br />Complete and submit a copy of the financial responsibility. <br />105. UST facility (Form A) and tank forms (Form B) on file with the EHD are not current. Any change of <br />information on these forms must be submitted to the EHD within 30 days of the changes. Per Savemart <br />Management Company, SSR Group Inc will begin lease take over for this facility in July 2012. <br />Immediately complete and submit a copy of the facility and tank forms to the EHD. Complete a separate <br />tank form for each tank and submit copy of Form A & B. <br />105. UST facility has not submitted a BOE Maintenance Fee Account Numbers. Contact California <br />State Board of Equalization to apply for all necessary tax ID numbers necessary to operate business. <br />Immediately complete and submit a copy of the facility form to the EHD. <br />106. The monitoring and response plans on site are not current and not approved by the EHD. The <br />monitoring and response plans must be current and approved by the EHD. Complete and submit a copy <br />of the monitoring and response plans for approval by the EHD. An approved copy will be returned for <br />your records. <br />108. Secondary containment testing was last performed on July 29, 2008 and was due by July 2011. <br />Testing has not been completed and is 12 months past due. Secondary containment testing is required <br />once every 36 months. Immediately schedule this test and provide 48 hours notification to the EHD. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector: Received By: Title: <br />t <br />FHn 9�_m R— namam7 Paae 3 UST INSPECTION REPOR <br />
The URL can be used to link to this page
Your browser does not support the video tag.