My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_JULY 2012-OCTOBER 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_JULY 2012-OCTOBER 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2024 1:51:29 PM
Creation date
6/3/2020 9:54:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JULY 2012-OCTOBER 2013
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_JULY 2012-OCTOBER 2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
491
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sipov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of 6 <br />OFFICIAL INSPECTION REPORT <br />Date: 07/05/12 <br />Facility Address: SSR Group Inc 2375 North Tracy Blvd, Tracy <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />109, 110, & 111. Annual monitoring system certification, leak detector testing, and spill container testing <br />were last performed on August 31, 2009 and was due by August 2010. Testing has not been completed <br />and is almost two years past due. Test results from August 31, 2009 was never submitted to EHD. <br />These tests are required once every 12 months. Immediately schedule these tests and provide 48 hours <br />notification to the EHD. Please be aware that a follow up inspection will be charged at our current hourly <br />rate. <br />119 & 317. A permit was not obtained from EHD to temporary close. Savemart Management had an <br />agreement with EHD to monitor the site on a daily basis since the eviction of a former operator in <br />December 2010. UST were not in use since approximately July 2010 by SJVAPCD due to failure of <br />upgrading EVR system. Savemart has handled over the property to SSR Group Inc beginning of July <br />2012. It is unclear if the new operator intends to return the UST back to use or when it will be returned <br />back to use. No person shall abandon an UST system without complying with the requirements of HSC <br />25298. Immediately obtain a permit from the EHD to temporarily close this UST system. <br />116. The UST system at this facility has been identified by the State Water Resources Control Board to <br />be located within 1000 feet of a public drinking water well and must test the UST system once using an <br />enhanced leak detection test. This testing has not been completed. Immediately schedule this test and <br />provide 48 hours notification to the EHD. Provide copies of the test results within 60 days after test has <br />been performed. <br />204 & 205. Designated operator has not been identified for this facility and monthly visual inspections <br />has not been performed. Last designated operator report for this facility was on August 31, 2009. There <br />has not been any monthly visual inspection reports since then nor is there a current designated operator <br />for this facility. The designated operator duties includes documenting all the alarms from the attached <br />alarm history on each of the designated operator monthly inspection report and check that they were <br />responded to appropriately. Designated operator must document action taken in response to any <br />alarms. They must visually inspect the UST system for leaks, water, or debris during the monthly <br />inspection including spill containers and UDC sumps, and any tank top sump that had an alarm for which <br />there is no record of a service visit. Ensure that designated operators performing monthly inspections at <br />this facility are including all of the required information on the reports. Monthly visual inspection reports <br />must be on site for a minimum of 12 months. Submit to EHD an Owner Statement identifying who is the <br />current designated operator. Owner shall inform EHD if there is any change of designated operator <br />within 30 days of change. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Received By: <br />Title: <br />Thuy Tran (209) 468-8257 <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.