My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 11
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 2:48:03 PM
Creation date
6/3/2020 9:55:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 11
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 11.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Lawrence Livermore National Laboratory <br />Site 300 <br />Bld . No. 882 <br />Site Address: Corral Hollow Road <br />City: Trac <br />Zip: 95376 <br />Facility Contact Person: Willie Smith <br />Contact Phone No: 925) 423-0414 <br />Make/Model of Monitoring System: USD LA -02 <br />Date of Testing / Service: 10-28-2003 <br />B. Inventory of Equipment'Tessted/Certified <br />Check the approLdate boxes to indicates cific aqui went ins cted/serviced: <br />Tank ID: DIESEL 882-DIUI IT Tank ID: <br />❑ In -Tank ng Probe. <br />Model: <br />■ Annular Space or Vault Sensor. <br />Model: LALS-1 <br />■ Piping Sum / Trench Sensor(s). <br />Model: LALS-1 <br />❑ Fill Sump Sensors). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Le I Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on <br />LENE2 <br />❑ In -Tank Gau 'n& Probe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ PipipA Sum / Trench Sensors). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on <br />Page 2 <br />Tank ID Tank ID: <br />❑ In -Tank Gaugipg GaugingProbe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Pipi2g Sum / Trench Semo s . <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / Hi -Level Sensor. <br />d Model: <br />❑ Other (specify equipment type and model in Section E on <br />Page 2 <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sum / Trench Sino s . <br />Model: <br />❑Fill Sump Sensos . <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / Hi -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on <br />Page 2 <br />Dis enser ID: NO DISPENSERS Dis eraser ID: <br />❑ Dispenser Containment Sensor(s). I Model: ❑ Dispenser Containment Sensor(s). I Model: <br />❑ Shear Valve(s). ❑ Shear Valve(s). <br />❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br />Dis enser ID: Dis enser ID: <br />❑ Dispenser Containment Sensor(s). I Model: ❑ Dispenser Containment Sensor(s). I Model: <br />❑ Shear Valve(s). ❑ Shear Valve(s). <br />❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />Attached a ennv of tho mnnrt- /check all that annlvl- ❑ Svctem set -eon ❑ Alarm hietory renort <br />Technician Name: Brian Thornton Si tures s--- - "-----�.. <br />Certification No. 02-0276 License No. 724513 <br />Testing Company Name: Thornton &Son Electric Phone No. 408 946-1015 <br />Page 1 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.