Laserfiche WebLink
CLOSURE REPORT FOR UNDERGROUND STORAGE TANK 836-DlUl <br /> feet of supply and 13-feet of return line, and 7-feet of vent Piping. Thisip ping was removed <br /> on 6/22/94 and manifested with UST 827-D2U1 and associated piping 7/22/94) The UST <br /> 827-D2U1 Closure Report will be submitted to your office at a later date <br /> Type/diameter of aboveground piping: 2-inch diameter vent piping. <br /> Type/diameter of underground piping: 1-inch diameter supply and return piping; and 2-inch <br /> diameter vent piping. <br /> Any piping closed in place: [X]Yes [ ]No <br /> Approximately 27-feet of supply and 27-feet of return line located under the concrete was <br /> closed in-place Also approximately 22-feet of vent pining was left in-place <br /> Describe where the piping was closed in place,and how it was closed(e.g.grouted and capped): <br /> On March 18 1994 PetroTek performed a pressure test on the12iTing which resulted in the <br /> indication of at least 2 leaks (see OTHER OBSERVATIONS). Supply,return,and vent lines <br /> were then grouted and capped from the asphalt/concrete interface to the emergency <br /> generator. <br /> Underground concrete tank anchoring structure(s)were present: [ ]Yes [X]No <br /> Size and location of the concrete tank anchoring structure(s): N/A <br /> Description of tank and piping condition (corrosion, pitting, holes, etc.): The tank had some <br /> corrosion,but appeared to be intact. Photographs of the tank were taken by Marion Heaton <br /> (3/11/94). The tank was in decent condition,and there was no staining in the excavation after <br /> the tank was removed. <br /> The tank and piping*were transported by: Erickson Inc. <br /> (*except pipe noted as having been removed and manifested with later tank closures) <br /> The tank and piping* were disposed of as: Non-RCRA Hazardous Waste. Solid (Empty <br /> Containers Last Containing Diesel Fuel with associated pining). Date: 3/11/94 <br /> (*except pipe noted as having been removed and manifested with later tank closures) <br /> Name and address of disposal facility: Erickson Inc. (Hauler Registration No. 0019), <br /> 255 Parr Blvd.Richmond,CA 94801 (510)235-1393. <br /> [X] LLNL Hazardous Waste Disposal Requisition and Uniform Hazardous Waste Manifest <br /> "TSD Facility to Generator" copies for the tank and piping shipped 3/11/94 and for <br /> the piping shipped on 6/22/94 and 7/26/94.are enclosed as Appendix C. <br /> [N/A] UST Disposition Tracking Record enclosed (San Joaquin County Only). <br /> SIC Tank#39-1945-27. <br /> EXCAVATION INFORMATION: <br /> Soil was excavated by: PetroTek. Date: 3/11/94 <br /> Shoring was required: [ ] Yes [X] No <br /> Type of shoring used: N/A. <br /> Soil types encountered within the tank excavation: <br /> 0-11 ft. Brown Silty Gravel <br /> Describe any potential contaminant pathways such as tree roots or underground utility lines <br /> discovered in the excavation: Sanitary sewer line was located next to the tank excavation. <br /> Describe any odors or staining found in the fill material or native soil: None. However,a"sliVht <br /> odor" was indicated on sample#TK01-01-836-D1U1-SP-SO that had been collected from the <br /> excavated soil stockpile. <br /> Soil Disposal Information: <br /> [ ] Not Applicable. (Soil and backfill placed back into the tank excavation and piping trench). <br /> The volume of disposed soil: N/A cubic yards. <br /> The soil was transported by: N/A <br /> The soil was disposed of as: N/A Date: N/A <br /> The concrete tank anchoring structure(s)was disposed of with the soil: <br /> [ ]Yes [ ]No [ ]Left in the Tank Excavation [X]N/A <br /> If no,describe how the concrete tank anchoring structure(s)was disposed of: N/A <br /> Name and address of disposal facility: N/A <br /> 2 <br />