My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 7
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_FILE 7
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/22/2022 1:28:25 PM
Creation date
6/3/2020 9:55:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 7
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_FILE 7.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
509
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS otlrvI84 <br /> The following represent:minimum scrupling criterion required for closure compliance. Soil samples collected shall be <br /> representative of native soils beneath the tank's invert(tank's bottom)at a collection depth not to exceed 2- 3 feet. If <br /> contamination is documented during closure,tui Unauthorized Release Notification must be completed and submitted within five <br /> (5)working days pursuant to California Health&Safety Code.Section 25295• <br /> WATER NOT PRESENT IN THE TANK PIT <br /> TANK TANK SIZE MINIMI rM M rMBER LOCATION OF SOIL SAMPLES <br /> # cGahlons) of SOIL SAMPLES <br /> < 1.iMN) lper Tank Fill OR Purnp End of Tank <br /> K79- ki X 0 - I0.(N N I 2 per Tank t at each End of Tank <br /> G,lrl. <br /> ELL�i <br /> ? orClore prr Tank Ends acrd Middle OR generally <br /> s acrd adon_the lengdn of the Tank <br /> "Assumes removal of anv potential slab below the tank. <br /> PIPING AND STOCKPILE <br /> 879- PIPING SOIL Sr1MPLES l Sample every 20 lineal Feet <br /> 6211TANK & PIPING STOCKPILE SANIPLLS 2 Saniples every 50 cubic vards <br /> WATER IS PRESENT IN TANK PIT <br /> TANK TANK SIZE M1MMiJM LOCATION of SOIL MINIMUM NUMBER of <br /> # (Gallons) NUMBER of SOIL SAMPLES WATER SAMPLES <br /> -�< 10.(X)O SAMPLES From wall next to tank <br /> Single Tank 2 ends a i soil/groundwater I <br /> 1111 <br /> > 10.(NN) OR From wall next to tank <br /> Tank Cluster 4 ends at soil/groundwater t <br /> interlace <br /> SLAB PRESENT 1N THE TANK PIT <br /> Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in <br /> order to collect the saunples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br /> TAM{ TAMC SIZE MINIlNLIM NUMBER LOCATION of SOIL SAMPLES <br /> # (Gallons) of SOIL SAMPLES <br /> < 1.000 3 per Tank tenter and Ends OR Side-,of Tank <br /> 1.000- 10.000 5 per Tank Center and Ends OR Sides of Tank <br /> > 10.000 5 OR More per Tank along Ends and Middle and generally spaced ag the <br /> leneth of the Tank <br /> EH 23 Ul7 (Rev 7/10/92) <br /> 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.