My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2011-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 11:55:25 AM
Creation date
6/3/2020 9:56:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2012
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231995_1403 W COUNTRY CLUB_2011-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT PIPING SUMP TESTING <br />Test Method By: o Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descrintion Tank #1 Tank 92 Tank #3 <br />Tank product <br />Diesel <br />Gasoline - 87 <br />Gasoline - 91 <br />Sump material <br />FRP <br />FRP <br />FRP <br />Sump diameter (inches) <br />48 <br />48 <br />48 <br />Sump depth (inches) <br />80 <br />74 <br />73 <br />Height from tank top to highest <br />piping penetration (inches) <br />22 <br />23 <br />28 <br />Height from tank top to lowest <br />electrical penetration (inches) <br />41 <br />36 <br />36 <br />Method of sump attachment to tank <br />Tank Collar <br />Tank Collar <br />Tank Collar <br />Condition of sump prior to testing <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Unknown <br />Unknown <br />Was fail-safe verified to be operational? <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Depth of water level from tank top (inches) <br />24 <br />31 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />Test start time <br />12:46 PM <br />12:07 PM <br />Initial Probe Reading <br />3.6587 <br />1.8868 <br />Test end time <br />1:02 PM <br />12:23 PM <br />Final Probe Reading <br />3.6595 <br />1.8862 <br />Test duration (hr:min) <br />0:16 <br />0:16 <br />Change in water level (± 0.0000 inches) <br />0.0008 <br />-0.0006 <br />Pass/Fail threshold (±0.0020 inches /; Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />Comments: <br />This is a retest of the 91 and diesel STP sumps only. <br />0 2011 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.