My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2011-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 11:55:25 AM
Creation date
6/3/2020 9:56:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2012
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231995_1403 W COUNTRY CLUB_2011-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPENSER CONTAINMENT PDC) TESTING <br />Test Method By: O Manufacturer <br />Test Method Uses: o Pressure <br />Measuring Equipment Used: INCON <br />• Industry Standard o Professional Engr o Other (see below) <br />O Vacuum • Hydrostatic o Other (see below) <br />TS -STS (Electronic Sump Test System) <br />Description Disp # 1/2 <br />Disp # 3/4 Disp # 5/6 Disp # 7/8 <br />UDC manufacturer Bravo <br />Bravo Bravo Bravo <br />UDC material Steel <br />Steel Steel Steel <br />UDC depth (inches) 12 <br />12 12 12 <br />Height from UDC bottom to highest <br />piping penetration <br />Height from UDC bottom to lowest <br />electrical penetration <br />— <br />Condition of UDC prior to testing <br />Port <br />ion of UDC tested <br />Type of shut -down present <br />Float <br />Float <br />Float <br />Float <br />Was sensor removed for testing? <br />Was sensor properly replaced after testing? <br />Depth of water level from UDC bottom (in.) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Initial Probe Reading <br />Test end time <br />Final Probe Reading <br />Test duration (hr:min) <br />Change in water level (t 0.0000 inches) <br />Pass/Fail threshold (10.0020 inches / ; Hr.) <br />TEST RESULT <br />Comments: <br />0 2011 Walton Engineering, Inc. <br />ion of UDC tested <br />Type of shut -down present <br />Float <br />Float <br />Float <br />Float <br />Was sensor removed for testing? <br />Was sensor properly replaced after testing? <br />Depth of water level from UDC bottom (in.) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Initial Probe Reading <br />Test end time <br />Final Probe Reading <br />Test duration (hr:min) <br />Change in water level (t 0.0000 inches) <br />Pass/Fail threshold (10.0020 inches / ; Hr.) <br />TEST RESULT <br />Comments: <br />0 2011 Walton Engineering, Inc. <br />
The URL can be used to link to this page