E <br />SWRCB, January 2002 Page 5 of 8 <br />7. UNDER -DISPENSER CONTAINMENT9,!PC) TESTING OCT 1 9-2D16- <br />Test Method Developed BY: <br />❑ UDC Manufacturer 1Z Industry Standard [] Professional Engineer <br />❑ Other (Specify) ENVIRONMENTAL HEM <br />Test Method Used: <br />C] Pressure <br />0 Other (Specify) <br />❑ Vacuum <br />0 Hydro DEPART MENT <br />Test Equipment Used: INCON SUMP TESTER <br />12 <br />IUDC N 314 <br />Equipment Resolution: + 1- 0.002" <br />UDC # 516 UDC # 718 <br />UDC Manufacturer: <br />BRAVO <br />BRAVO <br />BRAVO <br />BRAVO <br />UDC Material: <br />STEEL <br />STEEL <br />STEEL <br />STEEL <br />UDC 2e p±: <br />12" <br />12" <br />12" <br />12" <br />Height from UDC Bottom to TOP <br />of Highest Piping Penetration: <br />3.5" <br />3.5" <br />3.5" <br />3.5" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />N/A <br />NIA <br />NIA <br />NIA <br />Condition of UDC prior to <br />testing: <br />DIRTY <br />DIRTY <br />DIRTY <br />DIRTY <br />Portion of UDC Tested <br />2" ABOVE <br />PENETRATION <br />2" ABOVE <br />PENETRATION <br />2" ABOVE <br />PENETRATION <br />2" ABOVE <br />PENETRATION <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />[]Yes C]No ®NA <br />[]Yes E]No [DNA <br />E]Yes []No ®NA <br />[]Yes ONo SNA <br />Turbine shutdown response time <br />N/A <br />NIA <br />NIA <br />NIA <br />Is system programmed for fail- <br />safe shutdown? <br />OYes ONo ®NA <br />[:]Yes []No ®NA <br />[I Yes [I No 0 NA <br />[]Yes CNo ®NA <br />Was fail-safe verified to be <br />operational?* <br />OYes []No ®NA <br />[3 Yes [:] No 0 NA <br />[]Yes [--]No ®NA <br />❑Yes [] No ®NA <br />Wait time between applying <br />pressurelvacuum/water and <br />starting test <br />10 MIN <br />10 MIN <br />10 MIN <br />10 MIN <br />Test Start Time: <br />1:59 <br />1:59 <br />12:21 <br />12:57 <br />Initial Reading (111): <br />2.1725" <br />1.6677" <br />0.2366" <br />1.3844" <br />Jest End Time: <br />2:14 <br />2:14 <br />12:36 <br />1:12 <br />Final Reading (RF): <br />2.1725" <br />1.6676" <br />0.2364" <br />1.3856" <br />Test Duration: <br />15 MIN <br />16 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF -P4): <br />0.00001, <br />-0.00011, <br />- 0.0002" <br />0.0012" <br />Pass/Fail Threshold or Criteria: <br />+ I - 0.002" <br />+ I - 0.002" <br />+ I - 0.002" <br />+ I - 0.002" <br />Result: <br />0 Pais 0 Flail <br />0 Pan -E] Fall <br />0 Pan 0 Fail <br />[@ Pass 0 Fail <br />-Test <br />Was sensor removed for testin ;? <br />0 Yes 0 No 0 NA <br />[]Yes ONo (ENA <br />FiYes oNo ®NA <br />DYes ONo ®NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />OYes ONo SNA <br />I <br />OYes ONo ®NA <br />I <br />[]Yes E]No SNA <br />FlYes ONo ®NA <br />I <br />Comments — (include information on repairs made prior to testing, and recommended�ollow-upfor failed tests <br />ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br />SENSOR FUNCTIONALITY WAS NOT CONFIRMED. THIS PROCEDURE IS NOT A PART OF SB989 TESTING. <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to My of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See S"CB LG -160) <br />a <br />