My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2013-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 1:49:12 PM
Creation date
6/3/2020 9:56:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2017
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231995_1403 W COUNTRY CLUB_2013-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
414
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Facility Name: <br />319 1 HSC 25291(e) <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd <br />Facility Address: <br />RY CLUB BLVD. STOCKTON <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />Date: <br />Mav 12. 2015 <br />■V ■R ❑COSI <br />320 <br />HSC 25290.1(c3), <br />25290.1(c3) <br />Secondary containment not constructed to prevent water intrusion <br />❑ V <br />❑ R <br />❑ COS <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />❑ V <br />❑ R <br />❑ COS <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V <br />❑ R <br />❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V <br />❑ R <br />❑ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V <br />❑ R <br />❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V <br />❑ R <br />❑ COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />❑ V <br />❑ R <br />❑ COS <br />327 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V <br />❑ R <br />❑ COS <br />328 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />❑ R <br />❑ COS <br />329 <br />CCR 2717.1(1) <br />Deposited petroleum into a red tagged UST <br />❑ V <br />❑ R <br />❑ COS <br />330 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V <br />❑ R <br />❑ COS <br />331 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V <br />❑ R <br />❑ COS <br />332 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />333 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />401 1 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br />402 CCR 2643(d) Daily monitoring of suction pipe (pre -Jan 1984) not performed ❑ V ❑ R ❑ COS <br />403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />2010 See below Unlisted Administration/Documentation violation ❑ V ❑ R ❑ COS <br />2030 See below Unlisted Operations/Maintenance violation ❑ V ❑ R ❑ COS <br />2060 See below Unlisted Design/Construction violation ❑ V ❑ R ❑ COS <br />Item # Remarks <br />104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />UST Tank Information forms for the the tanks are not current in CERS. The overfill protection for the fuel tanks <br />indicated audible/visual alarms as overfill. The facility is using flappers as overfill. The waste oil tank indicated exempt <br />for overfill protection. The waste oil tank is using audible/visual alarms as overfill. Any change of information must be <br />updated in CERS within 30 days of the changes. Immediately log into CERS, update the required information, and <br />submit for review by the EHD. This was corrected on site. <br />This is a Class II violation. <br />Received by Inspector: Phone: Date: <br />(initial): 111 FATINAH ZAREEF, REHS (209) 953-7311 05/12/2015 <br />Page 3 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.