SWRCB, January 2002 • <br />0 C T 21 2013 Page _5_ of _7 <br />7. UNDER-DISPENSERCONTAINMENT(UDC)T. $tTINV.*IAAcwa-rnt <br />Test Method Developed By: <br />' <br />El UDC Manufacturer ® Industry Stan IEALT <br />ElOther (Spec) <br />n ineer <br />g <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Spec) <br />❑ Vacuum <br />® Hydrostatic <br />Test Equipment Used: INCON SUMP TESTER <br />Equipment Resolution: + / - 0.002" <br />UDC Manufacturer: <br />UDC # 1/2 <br />BRAVO PAN <br />UDC # 3/4 <br />UDC # 5/6 UDC # 7/8 <br />BRAVO PAN <br />BRAVO PAN BRAVO PAN <br />UDC Material: <br />STEEL <br />STEEL <br />STEEL <br />STEEL <br />UDC Depth: <br />12" <br />12" <br />12" <br />12" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />3.50" <br />3.50" <br />3.50" <br />3.50" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />NIA <br />N/A <br />N/A <br />N/A <br />Condition of UDC prior to <br />testing: <br />DRY <br />DRY <br />DRY <br />DRY <br />Portion of UDC Tested <br />ABOVE <br />PENETRATIONS <br />ABOVE <br />PENETRATIONS <br />ABOVE <br />PENETRATIONS <br />ABOVE <br />PENETRATIONS <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />❑ Yes ❑ No ®NA <br />[-]Yes ❑No ®NA <br />[]Yes ❑No ®NA <br />❑ Yes ❑ No <br />® NA <br />Turbine shutdown response time <br />NIA <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?* <br />❑ Yes [:1No ®NA <br />[:1 Yes [-INo ®NA <br />El Yes [:1No ®NA <br />❑Yes [-]No <br />®NA <br />Was fail-safe verified to be <br />o erational?*[:]No <br />❑ yes [-]No ®NA <br />[:]Yes ®NA <br />El Yes [_1No ®NA <br />[]Yes ❑ No <br />®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />startina test <br />10 MIN <br />10 MIN <br />10 MIN <br />10 MIN <br />Test Start Time: <br />9:21 AM <br />9:21 AM <br />10:02 AM <br />10:02 AM <br />Initial Reading (Rj): <br />1.2569" <br />1.7500" <br />2.0406" <br />2.8978" <br />Test End Time: <br />9:36 AM <br />9:36 AM <br />10:17 AM <br />10:17 AM <br />Final Reading (RF): <br />1.2569" <br />1.7496" <br />2.0404" <br />2.8976" <br />Test Duration: <br />15 MIN <br />15 MIN <br />15 MIN <br />15 MIN <br />Change in Reading (RF -R,): <br />0.0000" <br />- 0.0004" <br />- 0.0002" <br />- 0.0002" <br />Pass/Fail Threshold or Criteria: <br />+/-0.00211 <br />+/- 0.002" <br />+/- 0.002" <br />+/-0.002" <br />Test Result: <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />0 Pass ❑ Fall <br />0 Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes [-]No ®NAfEl <br />es ❑ No ON <br />❑Yes ❑ No ®NA <br />❑ Yes ❑ No <br />®NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />❑ Yes ❑ No ®NAes <br />❑ No ®NA <br />❑ Yes ❑ No ®NA <br />El ❑ No <br />®NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br />ABOVE UDC'S ARE ALL EQUIPPED WITH CHAINS AND FLOATS AS PRIMARY LEAK DETECTION <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />