My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_1999-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:42:38 AM
Creation date
6/3/2020 9:56:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2010
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_1999-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />Page 7 of T <br />Test Method Developed By: <br />X UDC Manufacturer <br />X Industry Standard Professional Engineer <br />Other (Specify) <br />Test Method Used: <br />Pressure <br />Vacuum <br />X Hydrostatic <br />Other (Specify) <br />Test Equipment Used:Incon <br />Equipment Resolution: <br />UDC # _ 1 <br />UDC # 3-�Z <br />UDC #5 _ <br />UDC # 7_ <br />cturer: <br />7DCDepth: <br />,e l}1 b <br />l: <br />Height from UDC Bottom to Top <br />8® <br />of Highest Piping Penetration: <br />20 <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />e ke4wel <br />Cl <br />testing: <br />Portion of UDC Tested <br />AIS! lee <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />,,��cc�� <br />Yes No (!9D <br />Yes No <br />Yes No <br />Yes No <br />product and water)?* <br />Turbine shutdown response time <br />-- <br />— <br />-- <br />Is system programmed for fail- <br />Yes No a> <br />Yes No NA <br />Yes No <br />Yes No A <br />safe shutdown?" <br />Was fail-safe verified to be <br />Yes No <br />Yes No <br />Yes No <br />Yes No A <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />5 M 1',4t <br />/ S m o %o <br />! S m®Re <br />/ 5 ®�✓ <br />starting test <br />Test Start Time: <br />/ D : / 7 Ami <br />/v : ! 7 *01 <br />Initial Reading (Rj): <br />3 $O 4 <br />3-4 8 . <br />3 <br />Test End Time: <br />/0; 33 Aoi <br />/";z : / / <br />A " <br />Final Reading (RF): <br />/ - 3 $oS <br />S <br />T <br />, 3D 2 - <br />Test Duration: <br />Test <br />M / %ad <br />S M f h! <br />/;v <br />Change in Reading (RF -RI): <br />®&© I <br />' . 474qt:;,-Z <br />` C20-0 <br />Pass/Fail Threshold or Criteria: <br />+/-.002 <br />+/-.002 <br />+/-.002 <br />+/-.002 <br />-7 <br />�.. _n.. <br />fair, <br />ass- Lail' <br />Yes No <br />ass.' Fail°as <br />Yes No <br />Rail <br />Yes No <br />Was sensor removed for testing? <br />Yes No <br />Was sensor properly replaced and <br />Yes No N> <br />Yes No <br />Yes No TA <br />Yes No N -A <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />