My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 10:16:11 AM
Creation date
6/3/2020 9:56:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
AM PM HAMMER/I5 FOOD #83113
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232224_3250 W HAMMER_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Test Method Developed By: ❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ® Vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Vacuum Guage Equipment Resolution: 0.00 PSI <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Tank # 87 Master <br />Tank # 87 Syphon <br />Tank # 91 <br />Tank # <br />Is Tank Exempt From Testing?' <br />❑ Yes ® No <br />❑ Yes ® No <br />❑ Yes ® No <br />0 Yes 0 No <br />Tank Capacity: <br />12,000 <br />12,000 <br />12,000 <br />Tank Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Tank Manufacturer: <br />Unknown <br />Unknown <br />Unknown <br />Product Stored: <br />87 <br />87 <br />91 <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 min <br />10 min <br />10 min <br />Test Start Time: <br />10:OOam <br />11:00 am <br />12:00 am <br />Initial Reading (R,): <br />-5" hg <br />-5" hg <br />-5" hg <br />Test End Time: <br />11:00 am <br />12:00 pm <br />1:00 pm <br />Final Reading (Rd: <br />-5" hg <br />-5" hg <br />-5" hg <br />Test Duration: <br />1 Hour <br />1 Hour <br />1 Hour <br />Change in Reading (RF -R,): <br />0 psi <br />0 psi <br />0 psi <br />Pass/Fail Threshold or Criteria: <br />0 psi <br />0 psi <br />0 psi <br />Test Result: <br />Pass Fail <br />Pass ' ❑ Fail <br />Pass <br />Fail <br />El Pass ❑ Fail <br />Was sensor removed for <br />testina? <br />® Yes ❑ No❑ElYes <br />NA <br />Yes ❑ No❑ NA <br />®Yes❑ No❑NA <br />E]No❑ <br />NA <br />Was sensor properly replaced <br />and verified functional after ®Yes ❑ No❑ NA ® Yes ❑ No❑ NA ® Yes❑ No❑`NA ❑ Yes❑ No'❑ NA <br />testing? <br />Coments — (include information on repairs made prior to testing, and recommended follow-up for failed <br />tests) <br />ix- <br />k; <br />
The URL can be used to link to this page
Your browser does not support the video tag.