Comments — (include information on repairs made prior to testing, and recommended follow-up for failed <br />tests) <br />RECEIVE) - <br />MAY 2 8 2015 <br />PIPING SUMP TESTING [E <br />Test Method Developed By: ❑ Piping Manufacturer ❑ Industry Standard ❑ Profes'ionalEn meer <br />® Other (Specify) Caldwell Sump Tester <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Caldwell Sump Tester Equipment Resolution: 0.005 inches in <br />JjjjjSump <br />MM <br /># 87 <br />Master <br />Sump # 87 <br />Sump # 91 <br />Sump # <br />Piping <br />Sump # Vapor <br />Turbine <br />Syphon Piping <br />Turbine <br />Transition <br />Pot <br />Sump Diameter: <br />48 inches <br />48 inches <br />48 inches <br />36 inches <br />36 inches <br />Sump Depth: <br />44 inches <br />44 inches <br />44 inches <br />58 inches <br />58 inches <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top <br />27 inches <br />29 inches <br />26 inches <br />18 inches <br />36 inches <br />of Highest Piping Penetration: <br />Height from Tank Top to <br />17 inches <br />9 inches <br />10 inches <br />33 inches <br />33 inches <br />Lowest Electrical Penetration: <br />Condition of sump prior to <br />Dry/Clean <br />Dry/Clean <br />Dry/Clean <br />Dry/Clean <br />Dry/Clean <br />testing: <br />Portion of Sump Tested <br />33 inches <br />35 inches <br />32 inches <br />39 inches <br />37 inches <br />Does turbine shut down when <br />❑ Yes ❑ No <br />Oyes ❑No <br />Yes ❑No <br />❑Yes ❑No❑ <br />❑Yes ❑No❑ <br />sump sensor detects liquid <br />® NA <br />® NA <br />® NA <br />®NA <br />®NA <br />Turbine shutdown response <br />3 sec <br />3 sec <br />3 sec <br />3 sec <br />3 sec <br />time <br />Is system programmed for fail- <br />Yes No <br />Yes ❑No <br />Yes No <br />❑Yes _]No[] <br />❑Yes []No <br />safe shutdown <br />® NA <br />® NA <br />® NA <br />®NA <br />®NA <br />Was fail-safe verified to beYes <br />No <br />Yes No <br />Yes No <br />❑Yes ❑No❑ <br />❑Yes ❑No❑ <br />operational <br />® NA <br />® NA <br />® NA <br />®NA <br />®NA <br />Wait time between applying <br />pressure/vacuum/water and <br />5 minutes <br />5 minutes; <br />5 minutes <br />5 minutes <br />5 minutes <br />starting test: <br />Test Start Time: <br />8:00 am <br />9:00 am <br />;9:30 am <br />10:00 am <br />10:30 am <br />Initial Reading (R): <br />2"d Ring <br />2"d Ring <br />2nd Ring <br />2nd ring <br />2nd ring <br />Test End Time: <br />8:30 am <br />9:30 am <br />10:00 am <br />10:30 am <br />11:00 am <br />Final Reading (RF): <br />2"d Ring <br />2nd Ring <br />2"d Ring <br />2"d ring <br />god ring <br />Test Duration: <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Change in Reading (R, -R,): <br />0 change <br />0 change <br />0 change <br />0 change <br />D change <br />0.005 inches <br />0.005 inches <br />0.005 inches <br />0.005 inches in <br />0.005 inches in <br />Pass/Fail Threshold or Criteria: <br />in 1/2 hour <br />in 1/2 hour <br />in 1/2 hour <br />1/2 hour <br />1/2 hour <br />Test Result: <br />E Pass <br />® Pass <br />®Pass <br />0 Pass <br />® Pass <br />Fail <br />❑ Fail <br />❑ Fail <br />[I Fail <br />❑ Fail <br />Was sensor removed for <br />❑Yes []No <br />❑Yes [:]No <br />❑Yes ❑No <br />❑Yes ❑No <br />❑Yes ❑No <br />testing? <br />I ®N/A <br />®N/A <br />® N/A <br />®`N/A <br />®N/A <br />Was sensor properly replaced <br />❑Yes ❑No <br />❑Yes ❑No <br />❑ Yes ❑No <br />❑Yes ❑No <br />❑Yes ❑No <br />and verified functional after <br />®N/A <br />®N/A <br />®N/A <br />Z N/A <br />®N/A <br />testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed <br />tests) <br />