My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:49:50 PM
Creation date
6/3/2020 9:56:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1777\PR0232397\PERMANENT INJUNCTION 05-11-11.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e <br />SWRCB, January 2002 <br />Page 1 of 1 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: r Tank Manufacturer W Industry Standard r Professional Engineer <br />Other (Specify) <br />Test Method Used By: r Pressure r Vacuum W Hydrostatic <br />Other (Specify) <br />Test Equipment Used: VPLT Equipment Resolution: 0.00001 in. <br />Was sensor removed for testing? r Yes r No n NA cr," Yes r' No r NA r Yes r No r NA r Yes f" No r NA <br />Was sensor properly replaced and C+ Yes r Nor NA r Yes r Nor NA r Yes r Nor NA r Yes r No NA <br />verified functional after testing? <br />Comments ? (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />t If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is "NO" or "NA", the entire sump <br />must be tested. <br />STP Containment for <br />Tank 1 diesel - 1 <br />Sump Diameter: <br />48.00 in. <br />in. <br />in. <br />in. <br />Sump Depth: <br />48.00 in. <br />in. <br />in. <br />in. <br />Sump Material: <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />19.00 <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />10.00 <br />Condition of sump prior to testing: <br />good <br />Portion of Sump Tested' <br />21 <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />r Yes C" No NA <br />C Yes r Nor NA <br />r Yes r No C NA <br />C Yes C No r NA <br />Turbine shutdown response time <br />00:00:00 sec <br />sec <br />sec <br />sec <br />Is system programmed for fail-safe <br />shutdown?* <br />r Yes C` No {*. NA <br />t"` Yes r Nor NA <br />C" Yes i'' No ry NA <br />r Yes r Nor NA <br />Was fail-safe verified to be <br />P Yes r No 4* NA <br />r Yes (7 Nor NA <br />0 Yes r Nor NA <br />s; <br />r Yes Nor NA <br />—operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test <br />5 min <br />min <br />min <br />min <br />Test Start Time: <br />11:42:00 <br />Initial Reading (RI): <br />0.00000 in. <br />Test End Time: <br />12:42:00 <br />Final Reading (RF): <br />-0.00180 in. <br />Test Duration: <br />30 min <br />Change in Reading (RF -RD: <br />-0.00180 in. <br />Pass/Fail Threshold or Criteria: <br />+/-0.00200 <br />Was sensor removed for testing? r Yes r No n NA cr," Yes r' No r NA r Yes r No r NA r Yes f" No r NA <br />Was sensor properly replaced and C+ Yes r Nor NA r Yes r Nor NA r Yes r Nor NA r Yes r No NA <br />verified functional after testing? <br />Comments ? (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />t If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is "NO" or "NA", the entire sump <br />must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.