My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1777
>
2300 - Underground Storage Tank Program
>
PR0232397
>
COMPLIANCE INFO_2009-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 1:49:50 PM
Creation date
6/3/2020 9:56:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2013
RECORD_ID
PR0232397
PE
2361
FACILITY_ID
FA0003978
FACILITY_NAME
KAISER FOUNDATION - MANTECA
STREET_NUMBER
1777
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
20018034
CURRENT_STATUS
01
SITE_LOCATION
1777 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1777\PR0232397\PERMANENT INJUNCTION 05-11-11.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />6. PIPING SUMP TESTING <br />Page q of I <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />0 Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />0 Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment -Resolution: .002 <br />. <br />' <br />Sump # 1 Sump # <br />Sump # <br />Sump # <br />Sump Diameter: <br />43" <br />Sump Depth: <br />37" <br />Sump Material: <br />Fiberglass <br />Height from Tank Top to Top of <br />Vent 19" <br />Highest Piping Penetration: <br />Product 16" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />13" <br />Condition of sump prior to testing: <br />Dry <br />Portion of Sump Tested' <br />Water Level 19" <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />Yes No X NA <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />product and water)?* <br />Turbine shutdown response time <br />N/A <br />Is system programmed for fail-safe <br />shutdown?" <br />Yes No X NA <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />Was fail-safe verified to be <br />Yes No X NA <br />Yes No NA <br />Yes No NA <br />Yes No NA <br />o erationalf <br />Wait time between applying water <br />and startingtest: <br />l0 Minutes <br />Test Start Time: <br />8:45 <br />Initial Reading (R,): <br />.001 <br />Test End Time: <br />9:15 <br />Final Reading (RF): <br />.001 <br />Test Duration: <br />30 Minutes <br />Change in Reading (RF -R1): <br />.000 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />Test Result: <br />X Pass 0 Fail <br />Pass ❑ Fail <br />X Pass 0 Fail <br />0 Pass 0 Fail <br />Was sensor removed for testing? <br />X Yes ❑ No D NA <br />Yes 0 No ❑ NA <br />Yes 0 No ❑ NA <br />❑ Yes 0 No 0 N <br />Was sensor properly replaced and <br />X Yes 0 No D NA <br />Yes 0 No D NA <br />Yes ❑ No ❑ NA <br />D Yes D No DNA <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />No Turbin! System is not Conventional Suction, or Safe Suction. <br />System is equipped with Swing Check Valves at Tank Piping Sump, and Electric Pump Motors, <br />that push product, from Tank Piping Sump, to Day Tank, under pressure. <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -150) <br />
The URL can be used to link to this page
Your browser does not support the video tag.